Asus AR1000 Hardware referentiehandleiding - Pagina 30

Blader online of download pdf Hardware referentiehandleiding voor {categorie_naam} Asus AR1000. Asus AR1000 32 pagina's. Raid subsystem

Asus AR1000 Hardware referentiehandleiding
• 2-15. Power Supply

Power Supply Placement

The redundant power supply, located in the back of the chassis, consists of
one frame and two identical AT power modules. The LED indicators light
when both the input and output voltages are stable, and dim when either
the input or output voltage fails. A button located on the bottom-left corner
of the power supply disables the sounding of the audible alarm.

Replacing One Power Supply Module

Remove all cords connecting to the failed power module. The power sup-
ply module is secured by two spring clips (as circled above) and two hooks.
To remove the power module, use a screwdriver to push in the clips and
then slide the power module out. Insert a working power supply module.

Removing the Entire Power Supply Unit

Unplug all cords connecting to the power supply unit. Remove the eight
screws securing the power unit. Remove the side panel and then push the
power unit out of the chassis.
NOTE
The alarm will sound if any of the power supply unit is not
turned on before the system is powered on.
30
AR1000 RAID Subsystem Hardware Reference Guide
IV. Hardware Setup
Power LED
Spring Clip (one on each side)
Power Switch
Handle
Power LED
Spring Clip (one on each side)
Power Switch
Handle
AC Power In Connector
Monitor Power Connector
Alarm Reset Button