10.3 Menus
10.3.1 Menu A:
Menu A presents a summary of the current parameter setting.
In menu A, no parameters can be set. It serves only as a display.
Submenus that are not applicable in the current setting are not shown. For example: submenu A3 does not
show up if a factory preset level was chosen for sensitivity.
If you have to contact a technician from Baumer Electric because of a problem with the Scatec, always have
the parameter values on hand shown in this summary menu.
Submenu
Values
A1:
abcd
hhhhh iiiii
A2:
aa.a
Length Resol
User manual Scatec-10 / -15
Version 2017-10
Summary
Comments
efg
a False pulse suppression mode
0 = dynamic dead time
1 = synchronous dead time
2 = fixed dead time
3 = retro-reflective foil only
* = not activated
b Pulse delay
0 = immediate pulse delivery
1 = delayed pulse delivery
* = not activated
c running direction
0 = leading
1 = trailing
* = not activated
d Output pulse triggered by last edge
0 = first edge triggers output pulse
1 = last edge triggers output pulse
* = not activated
e Short pulse suppression
0 = no short pulse suppression
1 = short pulses will be suppressed
* = not activated
f A/B Encoder
0 = only A-channel of the encoder is used
1 = A- and B-channel of the encoder are used
* = not activated
g Sensitivity level
1 = highest
2 = medium
3 = low
4 = very low
* = customized
h Dead time or path
xxxyy length of dead time or path with unit
i Output pulse delay
xxxyy delay of the output pulse with unit
Output pulse length and encoder resolution
b.bb
aa.a
b.bb
www.baumer.com
output pulse length in milliseconds
encoder resolution in millimeters /
pulse
26 / 44