Blader online of download pdf Handleiding voor gebruik en onderhoud voor {categorie_naam} Electrolux AOFP061TU4. Electrolux AOFP061TU4 27 pagina's. Bcf 30kg 6 gn1/1 lw (240/3/60hz), bcf 50kg 10 gn1/1 lw (240/3/60hz) / bcf 100kg 20 gn1/1 lw (240/3/60hz) / bcf 70kg 10 gn2/1 lw (240/3/60hz) / bcf 180kg 20 gn2/1 lw (240/3/60hz) / bcf 30kg 6 gn1/1 lw (208/3/60hz) / bcf 50kg 10 gn1/1 lw (208/3/60hz) / bcf
D.6 LIST OF USER PARAMETERS
SYMBOL
MIN
Internal clock: Minutes
HOUR
Internal clock: Hours
DAY
Internal clock: Days
Internal clock: Month
MON
Internal clock: Year
YEAR
SrF
Indicates the cell temperature set point for the positive holding cycle and the conservation
phase after positive chilling
SFF
Indicates the cell temperature set point for the negative holding cycle and the conservation
phase after negative chilling
Temperature difference from absolute temperature/conservation set point, below which a
LAC
low temperature alarm is generated
Temperature difference from absolute temperature/conservation set point, below which a
HAC
high temperature alarm is generated
Indicates whether the LAC and HAC temperature limits are expressed as differential (d) or
CdiF
absolute (A).
Indicates duration of sanitation cycle
SLd
bCCy
Buzzer mode to indicate to indicate correct conclusion of a chilling cycle
'nob' = buzzer off
'bbl' = buzzer on for 30 seconds
"llb" = buzzer on until any key is pressed
Buzzer mode to indicate HACCP alarms
bFCy
Buzzer mode to indicate a generic alarm
bAll
"CUSTOM" standards: END OF POSITIVE CHILLING TEMPERATURE
CCEt
"CUSTOM" standards: END OF POSITIVE CHILLING TIME
CCtI
"CUSTOM" standards: END OF NEGATIVE CHILLING TEMPERATURE
CFEt
CFtI
"CUSTOM" standards: END OF NEGATIVE CHILLING TIME
CbSt
"CUSTOM" standards: START OF CHILLING TIME
EICE
The utility enables the utility of cycles ICE P1 and P2 instead of the custom programmes
tPrA
Indicates printing cycle during a chilling cycle. If set to 0, only the temperatures at the
beginning and end of the cycle are printed.
tPrC
Indicates the printing interval in conservation /holding. If set to 0, no value is printed.
Configuration of printout language:
PrnL
It = Italian, Gb = English, dE = German, fr = French, Es = Spanish, Se = Swedish
Adr
Network address
E485
Type of connection
"Prn" = Printer;
"PC" = Personal Computer;
Indicates applicable standards, whether "NF", "UK" or "CUSTOM"
nOr
Software version
REL
N.B. The default parameters (DEF.) may vary for different
appliance models.
25
RANGE
DEF.
0..59
0
0..23
0
1..31
1
1..12
1
0..99
0
-
3
25..10°C/F
-
-25
25..10°C/F
-50..125°C/F
5
-50..125°C/F
5
A/d
D
0..240
10
Nob
bbl
bbl
lbl
bbl
lbl
0..CbSt°C/F
10
0..360 min
110
-35..CbSt°C/
-18
0..360°C/F
270
0..127°C/F
63
Y/N
N
1..255 min
5
1..255 min
30
It/Gb/dE/fr/
Gb
Es/Se
1
01-FF
Prn/PC
Prn
nF, Uk, CuSt
Uk
-
-