Anderson VFI84 Bedieningshandleiding - Pagina 8
Blader online of download pdf Bedieningshandleiding voor {categorie_naam} Anderson VFI84. Anderson VFI84 15 pagina's.
required KW input from the burner at high fire. In the example shown on the graph, the
inlet process stream temperature is 400 °C, and the desired outlet temperature is 800°C.
This requires 172*10
of the burner needed. Select in Table 1 below, you can get the total capacity input.
VFI84 series burner provides 9 types of different capacity burners, table 1 below is the
VFI84 series Burner capacity.
Anderson Thermal Soluions(Suzhou)Co., Ltd
Anderson Thermal Solutions – VFI84 Burner Operation Manual
-3
KW/h, then multiply the total volume of the exhaust is the capacity
Fig 4 Burner Input Curve Diagram
BURENER TPYE
VFI84G2000
VFI84G2500
VFI84G4000
VFI84G5000
Table 1 VFI84 Series Burner Capacity
CAPACITY(KW)
MINIMUM
MAXIMUM
75
2000
100
2500
150
4000
200
5000
6