Your Spindeck is manufactured to the highest standards and underwent strict quality
inspection before leaving the factory. Despite this, you may encounter difficulty due to
improper installation, connection, or shipping damage. The following are a few examples,
and their most likely causes.
The platter doesn't turn although the unit is powered on:
The unit is not properly connected to the main power supply.
There is no power at the wall outlet.
Drive belt is not fitted or has slipped off the motor pulley or platter.
No signal through one or both channels:
No signal contact from the cartridge to the internal tonearm wiring. Check
that the four small wires attached to the rear of the cartridge are attached
and no wires are faulty.
Faulty contact between the Tonearm and the Phono input on your Spinbase
or amplifier. Make certain both plugs are firmly and fully inserted.
The unit is not connected to a phono input designed for a magnetic cartridge.
Line or Aux inputs are not suitable for Spindeck. If you do not have a
magnetic phono input on your amplifier a separate phono preamp is required.
Contact Andover Audio or your dealer for a suitable preamp.
Amplifier is not switched on, or an incorrect input selected. If using a vintage
amplifier, make sure the "Tape Monitor" switch is not engaged.
Stong hum on phono input:
No ground connection to amplifier.(Note that due to the high gain required of
phono circuits, it is normal to have a slightly higher noise level than typical
auxiliary line-level sources such as CD players, DACs, or radio tuners.)
Distorted or inconsistent sound from one or both channels:
The tracking force may be insufficient.
The stylus or cantilever may be damaged.
There may be too much dust on the stylus.
The stylus may not be fully seated in the cartridge body.