DSC PowerSeries PC1616 Installatiehandleiding - Pagina 5

Blader online of download pdf Installatiehandleiding voor {categorie_naam} DSC PowerSeries PC1616. DSC PowerSeries PC1616 17 pagina's. System enhancement module
Ook voor DSC PowerSeries PC1616: Installatiehandleiding (13 pagina's), Beknopte handleiding (4 pagina's), Installatiehandleiding (20 pagina's), Handmatig (18 pagina's)

DSC PowerSeries PC1616 Installatiehandleiding
Testing:
Power up system
Program options as required (See Programming Section on reverse side)
Note: For advanced programming refer to the PC1616/1832/1864 Reference manual
Violate, then restore zones
Verify correct Reporting Codes are sent to the Central Station
Troubleshooting:
LCD5500 LCD Programmable-Message Keypad
Press [✱][2] to view a trouble condition.
The trouble light will flash and the LCD will display the first trouble condition present.
Use the arrow keys to scroll through all trouble conditions present.
NOTE: When additional information is available for a specific trouble condition a [✱] will appear on the display.
Press the [✱] key to view the additional information
LED Keypads, LCD Fixed Message Keypads
Press [✱][2] to view a trouble condition.
The trouble light will flash.
Refer to the Trouble Summary chart below to determine the trouble condition(s) present.
Trouble Summary:
Light [1]✱ Service Required - Press [1] for more information
[1] Low Battery
[2] Bell Circuit
[3] General System Trouble
[4] General system Tamper
[5] Module Supervision
[6] RF Jam Detected
[7] PC5204 Low Battery
[8] PC5204 AC Failure
Light [2] AC Trouble
Light [3] Telephone Line Trouble
Light [4] Failure to Communicate
Light [5]✱ Zone Fault -Press [5] for more information
Light [6]✱ Zone Tamper - Press [6] for more information
Light [7]✱ Wireless Device Low Battery - Press [7] for more information
Light [8] Loss of Time or Date
TESTING & TROUBLESHOOTING