3onedata IES2008 Snelle installatiehandleiding - Pagina 2
Blader online of download pdf Snelle installatiehandleiding voor {categorie_naam} 3onedata IES2008. 3onedata IES2008 2 pagina's. Unmanaged industrial ethernet switch
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3
Check and confirm the product is firmly installed on
DIN-Rail, and then mounting ends.
【Disassembling DIN-Rail】
Step 1
Power off the device.
Step 2
After lift the device upward slightly, first shift out the
top of DIN-Rail mounting kit, and then shift out the
bottom of DIN-Rail, disassembling ends.
Attention before powering on:
Power ON operation: first connect power line to the
connection terminal of device power supply, and then
power on.
Power OFF operation: first unpin the power plug, and
then remove the power line, please note the operation
order above.
【Power Supply Connection】
DC power supply
This series provide 3-pin 5.08 pitch power
input terminal blocks. Power supply range:
12~48VDC/24VAC
【DIP Switch Settings】
It provides 4-pin DIP switch for function settings,
among which "ON" is enable valid end.
The definitions of DIP switch are as follows:
DIP
Definition
Operation
1
Loop detection
Set the DIP switch to ON to
enable the loop detection
function.
2
Storm suppression
Set the DIP switch to ON to
enable the storm
suppression function.
3
Set the DIP switch to ON to
One-key VLAN
enable VLAN function, port
1 can communicate with
DIP
Definition
Operation
other ports, while other ports
are
other.
4
Flow control
Set the switch to ON to
enable
function
【Checking LED Indicator】
The function of each LED is described in the table as below:
LED
Status
Description
Power supply is connected and
ON
running normally
PWR
Power supply is disconnected
OFF
and running abnormally.
Ethernet port connection is
ON
active.
Link/ACT
Blinking
Data transmitted
(1-8)
Ethernet port connection is
OFF
inactive.
【Specification】
Panel
10/100Base-T(X) self-adapting
RJ45 port, full/half duplex
100M copper port
self-adaption, support
MDI/MDI-X self-adaption
Power indicator, interface
Indicator
indicator
Exchange attributes
Backplane bandwidth
1.6G
MAC table size
2K
Power supply
Input power supply
12~48VDC/24VAC
3 pins 5.08mm pitch terminal
blocks
Access terminal
Support anti-reverse connection
and over-current protection
Consumption
No-load
Full-load
isolated
from
each
Environmental Limits
Working temperature
Storage temperature
the
flow
control
Working humidity
Protection grade
MTBF
0.5W@24VDC
1.4W@24VDC
-40~75℃
-40~85℃
5%~95% (no condensation)
IP40 (metal shell)
540249 hrs