Atus LBB6152/01 Installatiehandleiding - Pagina 6

Blader online of download pdf Installatiehandleiding voor {categorie_naam} Atus LBB6152/01. Atus LBB6152/01 9 pagina's. Single storage rack, for paging receivers and ps-micro mobiles

Personal Security | Installation Manual
4

Functional

When the Paging Receiver/PS-Micro mobile is placed in the rack, its batteries will be charged (if the switch in the battery
compartment in the receiver/PS-micro mobile is set in the right position).

4.1 Bleep while in rack

Special for pagers a switch is built in the storage rack to decide if you want to
receive calls or not when a pager is in the storage rack.
By default the switch SW1 is set such that a pager will bleep when it receives
a call while placed in the storage rack.

4.2 No Bleep while in rack/Charge only

This type of storage rack has the option to disable the pager to receive
calls from the system. When SW1 is set In that situation the pager will not
bleep when the system sent a call to that particular pager.
Note: The internal switch SW1 in the storage rack, can be reached by
removing the bottom plate. When it is set to No-Bleep, the pager
will not receive any call – so it will not bleep when called,
calls are not stored in the pager's memory then.

4.3 LED indications

When a pager/PS-micro mobile is placed in the rack good positioning is indicated by the
LED
1
on top of the storage rack.
When the LED illuminates bright it indicates good positioning of the mobile.
To see the different positions of SW1 (Bleep or No-Bleep mode) the LED on the
storage rack will illuminate with reduced intensity when set in "No-Bleep" mode.

4.4 Reset Alarms (remote reset-absent)

When a PS-Micro mobile is placed in the storage rack while the mobile is in alarm state,
the alarm state of the PS-Micro mobile will be reset. This independent how is SW1 set.
If the Alarm Central is programmed such that 'remote reset' is enabled, the alarm state
in the central is reset too.
If a PS micro mobile is placed in the rack, the internal alarm-sensors are
disabled, besides this the mobile goes to absent-state in the system.

4.5 External Signalisation when in rack

When a pager is placed in the rack a relays becomes active. The relays
has 2 voltage free contacts, one Normal Open (NO) and a Normal Closed (NC)
contact which can be used for external signalisation if the rack contains a pager
or not.
This option can be used as a kind of external absent indicator.
The electrical values are 12Vdc-1Adc
Both pager receiver and a PS-Micro Mobile are detected.

4.6 Power Supply

The rack is powered from a 9-12 V power supply or car battery.
Connect the output power connector of the adaptor to the socket
Connect the external power adaptor into a mains wall socket.
The storage rack is now ready for operation.
4.6.1

Fuse

The Single Storage rack is equipped with a fuse F1, 250mA, to prevent overload.
The fuse is positioned inside the housing and can be reached by removing the bottom
cover, unscrew the Printed board to reach it.
Warning:
- Do not place the racks close to sources of heat, radiators or in direct
sunlight.
- IPS B.V. recommends that all critical and stationary equipment be
connected to an Uninterrupted Power Supply.
International Pagerservices B.V. | II_LBB615201_en_1817
NO BLEEP
BLEEP
NO BLEEP
BLEEP
BLEEP
NO BLEEP
NC
NO
NC
NO
2
at the rear of storage rack.
en | 6