INSTRUCTIONS
4 Installation Procedure
1. Push a small flat-bladed screwdriver into the slot in the centre of the
expansion port cover, and gently lift the cover away from the starter.
2. Line up the adapter with the expansion port. Gently push the adapter
along the guide rails until it clicks into the starter.
5 Installing the Remote Keypad
NOTE
The remote keypad can be safely connected or removed while the starter
is running. It is not necessary to remove mains or control voltage.
1. Measure and drill four holes for the mounting screws and two holes for
the DB9 connector (refer to
2. Apply the foam gasket to the back of the keypad.
3. Align the keypad over the holes and screw in place. Tighten the screws so
that the foam gasket is compressed to half its original thickness (torque
approximately 1 Nm).
NOTE
If the screws are too loose, the gasket will not provide IP65 protection.
Over-tightening the screws can damage the keypad, gasket or panel.
4. Plug the cable into the keypad and the soft starter.
5. Press the faceplate onto the front of the keypad.
2
1
Mounting Diagram
2
on back page).