TEL MODE – Cable Selection
Tests can be performed for either 6, 4 or 2 conductor cables. Two 8P to 6P Modular
Reducers are included to ensure correct cable plug mating with the testers' modular sockets.
The Remote Terminator cannot be used in the TEL Mode.
Enter TEL Mode from either the main menu on the screen or by pressing the blue coloured
button.
TEL
The initial TEL MODE screen is shown
opposite and is set for a 6 conductor cable.
Use the
UP / DOWN NAVIGATION
toggle between the 6, 4 & 2 conductor
modes (see screenshots below for the 4 and 2
conductor modes).
8

TEL MODE

The TEL Mode is capable of testing for the following faults:
Open circuit
Short circuit
Crossed wires
Connect the cable between the MAIN and LOOPBACK
sockets as shown in the diagram opposite using a modular
reducer if required.
Press the
TEST
The display will indicate a PASS and the type of cable
connected if there is no fault.
If there is a FAIL due to a Open-circuit, Short or Cross fault,
the applicable wire pair(s) will blink).
keys to
button.