4. After accordance of reference quantity (on the weighing surface) and the quantity shown on
the display press the button „PCS".
The single weight as well as the weight of the reference quantity has to be a minimum
weight of 1d (please read. page 13, technical details). In case the weight is too low the
display will
show „". Put a higher reference quantity on the weighing surface and repeat the
procedure. Now the scale is ready for counting.
5. Place the quantity you want to count on the weighing surface. The display will show the
quantity lying on the weighing surface.
6. You may repeat the procedure as often as you like.
7. By pressing the UNIT-button the scale will change to weighing mode.
8. The band in the display will show the usage of the weighing capacity.
Percentage mode
The percentage mode is only available at unit „g" .
While using a tare object it has to be tared before changing to percentage mode.
1. Place a reference unit on the weighing surface during operation in weighing mode.
2. Press the button PCS, to switch to Counting- / percentage-mode.
The display will show „P
3. By pressing ZERO (upwards) respectively Tare button (downwards) it is possible to choose
the percentage mode (100%).
This will happen in the following order: 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 200, 300, 400,
500, 600, 700, 800, 900, 1000, 100% and again 10.
4. After accordance of reference weight (on the weighing surface) and the quantity shown on
the display press the button „PCS"
The single weight as well as the weight of the reference quantity has to be a minimum
weight
of 1d (please read. page 13, technical details). In case the weight is too low the display will
show „". Put a higher reference quantity on the weighing surface and repeat the
procedure. Now the scale is ready for counting.
5. Place the object to weigh on the weighing surface. The display shows the percentage of the
weighing good according to the reference weight.
6. You may repeat the procedure as often as you like.
7. Durch Drücken der UNIT-Taste kehren Sie zur Gewichtsanzeige zurück.
8. Das Band der Gewichtsanzeige gibt die Auslastung der Kapazität wieder.
Overload
When the scale is overloaded, a peep-tone as well as the indication "------" in the display will