Ook voor ADEMCO Ademco VISTA-20P: Snelle installatiehandleiding (2 pagina's), Handleiding voor programmering (17 pagina's), Gebruikershandleiding (20 pagina's), Snelstarthandleiding (6 pagina's), Snelle installatiehandleiding (2 pagina's), Snelle installatiehandleiding (2 pagina's), Handleiding voor programmering (2 pagina's), Beknopte handleiding (2 pagina's)

ADEMCO Ademco VISTA-20P Handleiding voor programmering
Type 21
Arm-Away
Type 22
Disarm
Type 23*
No Alarm Response
Type 24
Silent Burglary
Type 77
Keyswitch
Types 90-93
Installer Defined
*The system can still be armed when these zone types are in a faulted condition.
Schedules
(installer code + [#] + [6] [4]; master code can only access schedules 01-16 for VISTA-20P, 01-04 for VISTA-15P, and
events 00-07 for both controls; VISTA-15P supports up to 8 schedules, VISTA-20P supports up to 32 schedules )
No.
Event
Device No.
(see list below)
for "01" events:
enter 01-18
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Events:
Master/Installer
01 = device on/off
02 = user access
03 = latch key report
04 = forced STAY arm
• Arms the system in Away mode when the zone is activated.
• Pushbutton units send the user number to the central station when arming or disarming.
• User code for button must be assigned.
• Disarms the system when the zone is activated.
• User code for button must be assigned.
• Can be used on a zone when an output relay action is desired, but with no accompanying alarm (e.g.,
lobby door access).
• Usually assigned to all sensors or contacts on exterior doors and windows where bells and/or sirens are
NOT desired.
• Provides an instant alarm, with NO audible indication at any keypad or external sounder, if the zone is
faulted when the system is armed in the Away, Stay, or Instant, modes.
• A report is sent to the central station.
• Assign to zone wired to a keyswitch.
• These zone types can be programmed for various custom responses. See data fields *182-*185.
UL: Zone types 90-93 may not be used as fire or burglar zones in fire or UL burglar alarm installations.
Group No.
Partition
for "02" events:
for "04-06" events:
enter 1-8
enter 1, 2, or 3
05 = forced AWAY arm
06 = auto disarm
07 = display "reminder"
Start Time/
Days
Installer Only
10 = display custom words 8-10
11 = peridoic test report
– 13 –
Stop Time/
Repeat
Days
(yes/no)
Random
(yes/no)