Autonics BD-065 Handmatig - Pagina 10

Blader online of download pdf Handmatig voor {categorie_naam} Autonics BD-065. Autonics BD-065 14 pagina's. Laser displacement sensors
Ook voor Autonics BD-065: Producthandleiding (6 pagina's), Producthandleiding (5 pagina's)

Autonics BD-065 Handmatig
-|Transparent setting

▣ Parameter Setting

Mode
Key
Run mode
Sensing
[AUTO] key
optimization
over 2 sec
Zero
[ZERO] key
adjustment
over 2 sec
HIGH sensitivity
[MODE]+[▲] key
adjustment
over 2 sec
LOW sensitivity
[MODE]+[▼] key
adjustment
over 2 sec
Auto sensitivity
[MODE] key
adjustment
within 2 sec
(Teaching)
Control output
[MODE]+ [AUTO]
type
key over 2 sec
HIGH PEAK
[▲] key
value
LOW PEAK
[▼] key
value
Parameter
[MODE] key
group
over 2 sec
guide|-
Laser Displacement Sensor
Description
Present value (PV) display
• Solo: Displays present value (PV).
• When using calculation: Displays the result of calculation, and calculation indicator (CALC) of
master amplifier unit turns on.
Setting value(SV) display
Can change the type of value by the [◀/▶] keys, and each recognition lamp turns on.
Setting range: HIGH setting value, LOW setting value, real distance value (RV), analog output,
bank (Displays [BANK- □ ] and all the recognition lamps turn off.)
Optimizes the level of laser emission and receiving sensitivity regarding the object color and
environment.
Execution: Execute automatically when entering the mode.
Sets the present value (PV) to the reference distance forcibly.
Execution: After entering the mode, push the [ZERO] key within 1 sec, or apply the signal to
external input wire for zero adjustment over 3 sec.
Dismiss: Push the [ZERO]+[MODE] keys over 2 sec, or apply the signal to external input wire of
zero adjustment over 3 sec.
※ If the present value is changed by zero adjustment, the setting values (HIGH SV, LOW SV etc.)
are not changed.
Sets the judgment output (HIGH/GO/LOW) range by manual input.
Can change the number of digit by the [◀/▶] keys, and setting value by the [▲/▼] keys.
The recognition lamps display the type of sensitivity adjustment.
Set the judgment output (HIGH/GO/LOW) range automatically.
Enter the auto sensitivity adjustment setting mode after set the type of teaching mode in
parameter 1 group.
• 1-point teaching
Sets the judgment output range by using present value (PV) of reference object height.
HIGH setting value=height present value×1.5
LOW setting value=height present value÷2
Setting: 1. '1P' is displayed on setting value (SV) display, push the [AUTO] key within 2 sec.
2. After teaching the object for 2 sec, set the judgment output range automatically by
applying the result.
• 2-point teaching
Sets the judgment output range by using present value (PV) of reference object step.
HIGH setting value=(step×1.5)+bottom height
LOW setting value=(step÷2)+bottom height
Setting: 1. '1P' is displayed on setting value (SV) display, push the [AUTO] key within 2 sec.
2. After teaching the object for 2 sec, '2P' is displayed on setting value (SV)
display, push the [AUTO] key within 2 sec.
3. After teaching the object for 2 sec, set the judgment output range
automatically by applying the result.
Sets the type of control/analog output.
Setting: Select the setting value by [▲/▼] key, and apply by [MODE] key.
• Setting range
control output 'OUT': NPN output 'NPN', PNP output 'PNP'
analog output 'A-OUT': Disable 'OFF', 4-20mA current output '4-20MA',
0 to 5V voltage output '0-5V', 1 to 5V voltage output '1-5V',
-5 to 5V voltage output '-5-5'
After setting is finished, flashes 'OUtSET' on present value(PV) display and 'END' on setting
value (SV) display 3 times, and returns to run mode.
Displays HIGH/LOW PEAK value.
If there is direction key input or no key input for 5 sec, returns to run mode.
If push the [▲/▼] key over 3 sec during HIGH/LOW PEAK value display mode, initializes the
value. If there is no value, displays 'HHHH' / 'LLLL'.
Enters to the parameter group 1 to 4.
E-15
-15