Autonics BWPK Series Producthandleiding - Pagina 2
Blader online of download pdf Producthandleiding voor {categorie_naam} Autonics BWPK Series. Autonics BWPK Series 4 pagina's. Slim plastic single-beam picking sensors

Cautions during Installation
• Be sure to install this product by following the usage environment, location, and
specified ratings. Consider the listed conditions below.
- Installation environment and background (reflected light)
- Sensing distance and sensing target
- Direction of target's movement
- Feature data
• If the installation environment has reflected light from the wall or floor, a interval
distance of at least 0.3 m is required.
• When installing multiple sensors closely, it may result in malfunction due to mutual
interference. Install it by referring to the interference protection and the installation
method in the manual.
• Do not use in places where the light-receiving sensor is exposed to direct sunlight or
where the ambient illumination is higher than the specification.
• Do not impact with a hard object or bend the cable excessively. That could decrease
the product's water resistance.
• Use this product after the test. Check whether the indicator works appropriately for
the positions of the detectable object.
Ordering Information
Thisisonlyforreference,the actual product does not support all combinations.
Forselectingthespecifiedmodel,followtheAutonicswebsite.
BWPK 25
-
05
❶
❶ Control output
No-mark: NPN open collector output
P: PNP open collector output
Product Components
• Product
Sold Separately
• Flat bracket (BK-BWPK-ST)
• L-shaped bracket (BK-BWPK-L)
Connections
Blue
0 V
Brown
+V
Black
■ NPN open collector output
Blue
12 - 24 VDCᜡ
Brown
01)
White
①
②
Black
LOAD
Brown
OCP
SCP
Blue
01)
White
①
②
01) P icking input (P.I): Contact or transistor is ON, and picking indicator operates.
①
①
①
②
②
②
Contact
NPN transister
Contact
• Picking indicator
: W hen external picking input (P.I) is short-circuited with OUT (black), it is operated same as ON/OFF status of
control output.
• OCP (over current protection), SCP (short circuit protection)
Setting Switch
Switch
No.
Function
[Emitter / receiver] Selection of
①
ON OFF
transmission frequency
-
[Emitter / receiver] Selection ON / flashing
②
③
for Picking indicator
②
[Emitter] Sensing distance mode
①
③
[Receiver] Selection of Operation mode
01) F requency A, B indicators turn ON at the same time.
• Instruction manual
• Protection bracket (BK-BWPK-P)
P.I. (emitter /
OUT (receiver) White
receiver)
■ PNP open collector output
Blue
12 - 24 VDCᜡ
Brown
01)
①
White
01)
White
①
Brown
OCP
SCP
Black
Blue
①
②
PNP transister
Setting
ON
Frequency B
01)
Flashing
Short mode
Dark ON
Dimensions
• Unit:mm,Forthedetaileddrawings,followtheAutonicswebsite.
A
Picking indicator (yellow) B
D
Stable indicator (green)
Emitter
30
B
18
C
A
2-Ø 4.2
Model
BWPK25-05(P)
Operation Timing Chart
■ Light ON mode
• In Dark ON mode, the waveforms are reversed.
• Picking indicator is operated by connecting picking input line and output line.
(If not connecting these, picking indicator is OFF regardless of operation mode.)
Operation Indicator
ON
●
②
Item
②
Power ON
Frequency A
operation
Frequency B
LOAD
operation
Stable light ON -
Unstable light
ON
Unstable light
OFF
Stable OFF
Flashing func.
ON
Over current
• The operations of 'Operation indicator' and 'Picking indicator(Red)' for stable light ON level, unstable light ON
level, unstable light OFF level, and stable light OFF level are for Light ON.
• Malfunction of synchronous line and over current, control output is OFF regardless of the mode.
OFF
Frequency A
ON
Long mode
Light ON
Frequency A indicator
(green)
E
Operation indicator (red)
Receiver
9.9
Setting
switch
Ø 4, 2 m
2-Ø 4.2
Product length (L)
Number of optical axis Sensing height
140 mm
5
ON Level
OFF Level
Flashing at 0.3 sec
OFF
◑
interval
Emitter indicator
Receiver indicator
Picking
Green
Green
Green
indicator
●
-
-
●
-
-
-
-
-
-
-
●
-
-
●
●
-
-
●
-
-
◑
-
-
●
◑ ◑
Frequency B indicator
C
(green)
30
D
9.9
18
E
Setting
switch
Ø 4, 2 m
100 mm
Stable light ON area
Unstable light ON area
Unstable light OFF area
Stable light OFF area
ON
Stable indicator
OFF
(green)
ON
Operation indicator
OFF
(red)
ON
Picking indicator
OFF
(yellow)
ON
Control output
OFF
Flashing simultaneously
◑ ◑
at 0.3 sec interval
Control
Picking
output
Red
indicator
-
-
-
-
-
-
-
-
-
ON
ON
●
●
OFF
●
●
OFF
◑
ON
◑ ◑
●
OFF