activTek INDUCT 10000 Handmatig - Pagina 12

Blader online of download pdf Handmatig voor {categorie_naam} activTek INDUCT 10000. activTek INDUCT 10000 16 pagina's. Electronic air purification system
Ook voor activTek INDUCT 10000: Handmatig (16 pagina's)

CHANGING THE BALLAST

WARNING: Disconnect power at the
3.
Remove the two (2) thumb nuts on the
top and bottom side of the ballast to pull
ballast from assembly.
5.
To reconnect wiring, insert wire into
the corresponding color connector.
Gently pull back after inserting wire
to ensure the wire is properly locked
into place.
UPPER (3 terminals)
• Black power wire in BLACK
• White power wire in WHITE
• GREEN is not used
LOWER (6 terminals)
• 2 Red wires in RED
• 2 Blue wires in BLUE
(INDUCT 10000 ONLY)
• 2 Yellow wires in YELLOW
12
breaker or fuse panel before
servicing unit.
2.
Open the ballast housing by
removing the four (4) thumb
screws then remove the cover.
4.
Remove the wires from ballast
by pressing a small screwdriver
into the wire release:
• INDUCT 10000 - 8 wires
• INDUCT 5000 - 6 wires
CAUTION: Never attempt to check
operation of the ActivePure®
cell(s) by direct observation.
Severe eye damage can result.
Use the indicator lamps on the
bottom of the ballast only.
CAUTION: Disconnect power at the
breaker or fuse panel before
servicing unit. Always follow
OSHA lockout procedures to
prevent accidental exposure
to electrical energy.