AIREDALE AIR 1-550.30 Installatie- en onderhoudshandleiding - Pagina 4

Blader online of download pdf Installatie- en onderhoudshandleiding voor {categorie_naam} AIREDALE AIR 1-550.30. AIREDALE AIR 1-550.30 16 pagina's. Steam/hot water unit heaters

UNIT MOUNTING

Table 4.1 - Maximum Mounting Heights
Horizontal Type 
Height (ft)
Model No.
Std. L.O.T.
WTC/WSC 18
8
9
WTC/WSC 24
9
11
WTC/WSC 33
10
12
WTC/WSC 47
12
14
WTC/WSC 63
14
16
WTC/WSC 86
15
17
WTC/WSC 108
17
19
WTC/WSC 121
16
18
WTC/WSC 165
19
21
WTC/WSC 193
18
WTC/WSC 258
19
22
WTC/WSC 290
20
23
WTC/WSC 340
20
23
➀ With horizontal louvers opened 30° from the vertical plane. WTC units have top and bottom piping connections, WSC units have side connections. All have copper tubes.
➁ V and PT models have copper tubes, VN and PTN models have cupronickel tubes. Mounting heights are maximum for heaters operating at standard conditions
(2 lbs. steam or 220°F water with 60°F entering air). Heights listed for Louver or Cone-Jet are with deflectors in fully-opened position. Refer to Figure 4.2 for correction of
mounting heights under other operating conditions. Maximum mounting height will be reduced as entering air temperatures exceed 60°F.
Figure 4.2 - Maximum Mounting Heights Correction Factors
1.3
1.2
1.1
1.0
.9
.8
.7
.6
.5
150
160
170
180
These correction factors are to be used as multipliers to correct the maximum recommended mounting heights of unit heaters when operated with steam pressures other
than 2 pounds or with water at other than average temperature of 220°F.
Figure 4.3 - Horizontal Unit Delivery
H
Figure 4.3 Vertical Cone Jet
H
4
"Power-Throw" Type ‚
Height (ft)
Model No.
Std. L.O.T.
WPC/WPN 279 ‚
16
WPC/WPN 333 ‚
17
WPC/WPN 385 ‚
17
WPC/WPN 500 ‚
18
WPC/WPN 610 ‚
20
WPC 952 ‚
21
2
5
190
200
210
220
230
Figure 4.6 - Vertical Truncone
H
No Deflector
Height (ft)
Model No.
Std.
WVC/WVN 42 ‚
11
WVC/WVN 59 ‚
14
WVC/WVN 78 ‚
15
WVC/WVN 95 ‚
15
WVC/WVN 139 ‚
18
WVC/WVN 161 ‚
20
WVC/WVN 193 ‚
22
WVC/WVN 212 ‚
22
WVC/WVN 247 ‚
26
WVC/WVN 279 ‚
30
WVC/WVN 333 ‚
30
WVC/WVN 385 ‚
30
WVC/WVN 500 ‚
37
22
WVC/WVN 610 ‚
36
WVC 952 ‚
37
Steam Pressure
10
20
30
240
250
260
270
280
Average Water Temp – F
Figure 4.4 - Vertical One-Way & Two-Way Louvers
H
AIR 1-550.30
Vertical Type with Deflectors ‚
Cone-Jet
Truncone
Height (ft)
Height (ft)
L.O.T.
Std.
L.O.T.
Std.
13
15
17
8
16
19
22
9
19
20
26
11
19
20
26
11
23
24
31
13
26
27
35
14
27
30
36
16
27
30
36
16
32
34
42
17
36
37
45
18
36
37
45
17
36
36
43
17
45
44
54
19
44
43
52
19
45
50
70
100
290
300
310
320
330
H
Louvers
Height (ft)
L.O.T.
Std.
L.O.T.
9
13
15
11
16
18
14
17
22
14
17
22
17
21
26
18
23
30
19
25
31
19
25
31
21
30
37
22
35
41
20
35
41
20
35
41
24
42
51
24
41
50
150
340
350
360
370
H