Gamo 621213554 Gebruiksaanwijzing - Pagina 2

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Gamo 621213554. Gamo 621213554 3 pagina's. Hand pump pcp

1. FEATURES
· Length: 24.1 in (630 mm) Closed ; 43.3 in (1,100 mm) Open
· Weight: 5.29 lb (2.4 kg)
· Max. Pressure: 310 BAR or 4500 psi.
· Folding Base Plate
· This PCP pump could be continuously used for more than 2 hours based on 200 BAR.
· Output nut: 1/8 BSP
2. ACCESSORY LIST
01 special key.
1 pc
02 high pressure stem sealing ring.
2 pcs
03 high pressure piston ring.
2 pcs
04 O ring.
5 pcs
05 outer tube piston ring.
2 pcs
06 check valve spring.
2 pcs
07 sealing gasket of bleed valve.
2 pcs
08 high pressure piston spring.
2 pcs
09 low pressure piston ring.
2 pcs
10 high pressure spool valve.
2 pcs
11 inlet hole one-way seal ball.
2 pcs
12 key.
1 pc
13 key.
1 pc
3. INSTALL
Following the graphic, connect the pressure gauge, the output hose and the 8 mm (0.31 in) quick
connector using the special key.
!
Moderate strength can be applied but do not over tighten it as this could cause the sealing
CAUTION:
ring between the pressure gauge / hose and base plate to be deformed and jammed. The rubber grip must
be tightened and should not be loose.
2
A- Rubber Grip
B- Pump Barrel
C- Base Plate
D- Pressure Gauge
E- Moisture Filter
F- Hose
G- Quick Connector
H- Test Plug
I- Bleed Valve
5. OPERATION
!
· It is important that you become familiar with the correct method of operation as the incorrect operation
could result in damage to the pump and possibly to the user.
· Please connect the pump and bottle, the connector will be supplied when you buy the bottle. Please
13
connect it according to the corresponding instruction manual.
!
properly used.
· Please make sure that the bleed valve is tightened.
When pumping the air, please be sure the hose is not knotted. Then pull and push the pump steadily. You will
begin to feel more resistance when the pressure in the bottle equals 100 BAR or above, this is normal.
· Please open the bleed valve screw to release the residual/excess air in the pump, barrel and hose. It is
normal to see a small amount of air and water leak from the bleed valve. You can easily remove the filler
probe/valve after releasing the air from bleed valve.
CAUTION:
Before starting to fill the bottle, please read the instruction manual to ensure the product is
WARNING:
4. TEST
Step 1: Put the test plug into the 8 mm (0.31 in) quick
connectors, open the bleed valve (the bleed valve is in the
back of the base). Continuously pump air about 20 times
(in order to do that, pull the handle all the way up rapidly
and push it all the way down using your own weight).
Step 2: Tighten the bleed valve and pump until the
pressure is up to 100 BAR, then open the bleed valve
quickly to release the air. After that, tighten the bleed valve
again, inflate the pressure up to 200 BAR. Please check
the pressure gauge to see if the needle has fallen. (If the
needle has fallen, there will be an air leak. The best way to
find a leakage point is to put the pump, hose and test plug
under water together).
3