IKEA IH8432WS0 Installatie-instructies en gebruiks- en onderhoudshandleiding - Pagina 8
Blader online of download pdf Installatie-instructies en gebruiks- en onderhoudshandleiding voor {categorie_naam} IKEA IH8432WS0. IKEA IH8432WS0 32 pagina's. Island canopy range hood
Non-Vented
(Recirculating)
installation
1. Assemble the 3 parts of the deflector with 2 screws provided.
When assembled the deflector should be 143/4 '' (37.5 cm) wide.
143/4''
_
@
(37.5 cm)
_o--_..
...............
A. Deflector
2=
Attach the deflector to the bracket with 4 screws.
3. Measure length of 8" (20.3 cm) vent needed to connect the
transition to the deflector.
NOTE: Vent should fit up inside deflector 1" (2.5 cm)
minimum.
4. Install vent between the transition and the deflector.
NOTE: To make vent installation easier, temporarily remove
the deflector from the cover support bracket and replace after
vent section is in place.
5. Seal all connections with duct tape.
1. Lift the chimney structure so that large end of keyhole slots
are over mounting lag screws.
2. Move chimney structure so that the mounting lag screws are
in the narrow end of the keyhole slots. Securely tighten lag
screws.
3. Two additional screws are provided for additional support, if
desired. Screw them in place.
Vented
Installations
Only
1. Fit vent system over transition piece.
2. Seal connection with duct tape.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout.
4=
A, Knockout
B, Terminal box cover
Install the UL- or CSA-listed
conduit
connector.
B
A, Conduit
B, Terminal box cover
C, Conduit connector
5. Run 3 wires, black, white and green (14 AWG) in l&. conduit
from service panel to terminal box.
6. Use twist-on connectors and connect black wires together.
7. Use twist-on connectors and connect white wires together.