CLEANING AND MAINTENANCE ( Cont. )
Cleaning and Maintenance of Washable Pre-Filter & Electronic Grid (Cont.)
4. Cleaning the Washable Pre-Filter & Electronic Grid
Put a very small amount of Dish Detergent such as Dawn
Please do not clean using acidic or alkaline detergent that can create rust on the surface of device.
Place the two washable filters in the bathtub
Fill the tub with warm water (not hot) to just cover the filters
Soak
(Do
NOT
Scrub)
the two filters for a good half hour to remove dust and grime
Drain the tub and rinse the filters under the shower head. Though the faceplate
does not need soaking, rinse both sides with the shower head as well.
Please take care not to damage any wiring while cleaning the electronic grid
If any electrical discharge wire is broken, the device will lose part or
all of its dust collecting capability.
Any broken wires should be thrown away instead of being left inside the unit.
Otherwise, a dangerous short-circuit or high-voltage sparks may occur.
Please contact
5. Air Dry
ONLY
all washed parts.
Air dry the pre-filter, electronic grid and faceplate overnight. Operating
a wet unit may cause electrical shock or malfunction.
If the front cover of the electronic grid is not properly installed,
the unit will not function.
Please make sure the plastic wrap for the electrical discharge wire
is located in its proper position.
6.
ONLY
if using AUTO SETTING, a New 'Clean Air Reference' is required after cleaning
Every time you remove the faceplate to clean the unit, if there is a power outage, or you power it off, or if you unplug the unit for
any reason, you will have to re-program a 'reference for clean air' if you are leaving your machine on AUTO.
This is the case because any memorized content will have been completely erased. See page 6 for instructions on resetting
the auto-sensor.
Electronic Grid Wire Replacement
It's unusual to break a grid wire if properly following the above instructions for cleaning the Electronic Grid. But, if it does happen, call
(800) 215-1689 to order a replacement wire(s).
~ CAUTION: The grid wire and spring ends may have sharp edges. Please, handle them with care. ~
The Electronic Grid should have 3 wires extending from a bottom 'hook', around the top and back down to another 'hook'. Place one spring
end on a bottom hook.
Wrap the wire with it's plastic coated center around the 3 pegs near the top of the grid assembly. Gently stretch the wire just enough to
place the spring end over the hook at the lower end of the grid assembly.
For additional visual instructions, see "Plasma Grid Wire Replacement" illustration at
http://aliveairpurifier.com/wp-content/uploads/2009/09/plasma-wire1.jpg
Alive Air 9-Stage Air Purifier Owner's Manual
[
NOT
for additional electrical discharge wire.
Do NOT
operate your air purifier until you've received and replaced the broken wire(s).
10
automatic dishwasher detergent]
Plastic Wrap
in the bathtub.