Kohler STRAYT K-72866T-NW-CP Handleiding voor installatie-instructies - Pagina 4

Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} Kohler STRAYT K-72866T-NW-CP. Kohler STRAYT K-72866T-NW-CP 14 pagina's. Desk-mount sensor faucet

Kohler STRAYT K-72866T-NW-CP Handleiding voor installatie-instructies
4 5
220V
0.75
0.5~1
0.1MPa
1 ~55°C
0.5~71°C
0.05~
1.
(2)
螺管
(4)
(8)
(6)
固定环
(2)
(1)
螺丝
2. 控制阀组件的安装固定
拧松
10
9
12
4
(LR06×4)
50/60Hz
2.0L/min
1
(3)
螺管
(1)
(5)
(7)
(8)
用十字螺丝刀
在面盆上。
11
9
13
12
PARAMETERS
Power: DC 4 pieces of AA size alkaline batteries
AC 220V, 50/60Hz
Senser Duration: Less than 0.75s
Shut-off Delay: 0.5~1s
Sensing Distance: Automatic adjustment
Flow Rate: No more than 2.0L/min at 0.1MPa.
Overtime Flowing Control: Automatically stop flushing when
the faucet senses an object for more than 1 minute
continuously
Ambient Temperature: 1~55°C
Supply Water Temperature: 0.5~71°C
Supply Water Pressure: 0.05~0.86MPa
3
4
5
1
6
8
2
7
11
10
13

INSTALLATION

How to Install the Faucet
1. Fixing the faucet and lavatory
Install the mounting tube (2) to the bottom
of the faucet (3), then slip the washer (4)
over the mounting tube and put them into
the groove on the spout. Insert the power
wire (8) and supply hose (1) into the
hole from underside of the lavatory.
From underside of the lavatory, slide the
washer (5), meter washer (6) and fixed
ring (7) onto the mounting tube (2).
Tighten screw to make faucet installed on
the lavatory.
2. Fasten control valve assembly
Unscrew valve cover screws (11) by
screwdriver, open valve cover (10).
Determine control box assembly (9)
installation location per rough-in; then
drill holes, and punch plastic expansion
tube (12) in. Place valve box against
the wall and then mount control valve
assembly on the wall by expansion
screws (13). Keep control box assembly
parallel to the wall.
1495650-T2-A