Aqua Flo AQUV-20R2 Gebruikershandleiding - Pagina 10

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Aqua Flo AQUV-20R2. Aqua Flo AQUV-20R2 16 pagina's. Ultraviolet disinfection system

(E) DISINFECTION PROCEDURE
5. Shut-off the supply valve again and open a faucet to depressurize the system. Open the filter housing, re-install the filter cartridge and then
re-attach the filter housing. Make sure that the UV system is ON.
6. Take off aerators (if any) on the faucets, open the supply valve slowly, and thoroughly flush all outlets until the chlorine smell is minimal.
7. You are ready to use the water now.
(F) BALLAST FOR AQUV UV SYSTEMS
Aqua Flo AQUV advanced micro-processor controlled electronic UV ballast is for use with Aqua Flo AQUV-8, AQUV-12 & AQUV-20 Systems.
It features both audio and visual alarm indicators to indicate the lamp operation and an integral annual lamp change reminder timer.
NORMAL DISPLAY: Number of days left before lamp expires and must be
replaced. Starts at 365 and ends at 0.
Press button to display the total running days of the unit since installation
(maximum 9999 days). Display goes back to default after 10 seconds.
"LF" - LAMP FAULT: If the lamp is disconnected or defective (burned out), the
display will show "LF" with the red LED on, and the ballast will beep every 2 seconds. If you press the button once, display will show
"lamp life remaining" and go back to "LF" after 10 seconds. If you press the button again before 10 seconds, display will show "total
running time" and then after 10 seconds go back to "LF". In the "LF" alarm do not consume water until you replace UV lamp and
cleared the alarm.
"A3" – LAMP EXPIRY: If the display shows "A3" alarm with red LED on and ballast beeps every 5 seconds, it indicates that the lamp has
expired. Do not consume water until lamp is replaced.
You can silence the alarm for 7 days by pressing and holding the button until "dELy" is displayed. You can silence the alarm 3 times
after which the alarm will not silence until you replace the UV lamp.
RESETTING THE LAMP EXPIRY TIMER: After replacing the UV lamp annually, you must re-set the ballast timer to clear the "A3"
alarm. To do this press and hold the button for approx 10 seconds until "rSET" is displayed. Release button and the ballast will emit a
long beep to confirm reset. Green LED will come on and red LED will turn OFF. Display will show "365" again.
10
(CONTINUED)
WARNING
Failure to follow disinfection procedure could result in
micro-biologically unsafe water leading to potential
illness or death.
DISPLAY
BUTTON RED LED
GREEN LED