Installing the Switch on a Tabletop

The S25P can be positioned on a stable tabletop. Four rubber standoffs are provided for that purpose in the
plastic bag in the switch shipping box. Keep the following in mind when using a tabletop for your S25P:
Ensure that your tabletop is stable and can handle the weight of the S25P or a stack of switches, if that
is the case, along with any added external power supplies.
Position the table for proper ventilation and easy access to separate power outlets for each device.

Installing the Switch in a Rack or Cabinet

The S25P provides three rack-mounting methods:

Two-Post Rack Mounting

Four-Post Rack-mounting with Threaded Rails
Four-Post Rack-mounting with Cage Nuts
Two-Post Rack Mounting
The S25P is shipped with the universal front-mounting brackets (rack ears) attached. Ensure that there is
adequate clearance surrounding the rack to permit access and airflow. If you are installing two S25P
switches side-by-side, position the two chassis at least 5 inches (12.7 cm) apart to permit proper airflow.
Position the chassis in the rack. Secure the chassis with two of the supplied screws through each bracket
and onto the rack post.
Figure 6 S25P Two-post (Front-mounted) Rack-mounting
Installing the S25P System
19