Dell PowerEdge 1855 Gebruikershandleiding - Pagina 5
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Dell PowerEdge 1855. Dell PowerEdge 1855 33 pagina's. Using dell blade servers in a dell poweredge high availability cluster
Ook voor Dell PowerEdge 1855: Informatie-update (2 pagina's), Snelstarthandleiding (12 pagina's), Handleiding gebruiken (44 pagina's)
Infiniband
Physical
Height
Width
Depth
Weight (maximum configuration)
Environmental
NOTE:
For additional information about environmental measurements for specific system configurations, see
www.dell.com/environmental_datasheets. The system is not for use in an office environment.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Back to Contents Page
Ten 4X ports
3.302 cm (1.3 in)
13.081 cm (5.15 in)
27.432 cm (10.8 in)
1.8 kg (4 lb)
10° to 35°C (50° to 95°F)
NOTE:
Decrease the maximum temperature by 1°C
(1.8°F) per 300 m (985 ft) above 900 m (2955 ft).
–40° to 65°C (–40° to 149°F)
8% to 85% (noncondensing) with a maximum
humidity gradation of 10% per hour
5% to 95% (noncondensing)
0.25 G at 3–200 Hz for 15 min
0.5 G at 3–200 Hz for 15 min
One shock pulse in the positive z axis (one pulse on
each side of the system) of 41 G for up to 2 ms
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms
–16 to 3048 m (–50 to 10,000 ft)
–16 to 10,600 m (–50 to 35,000 ft)