Dell EMC VxFlex Ready Node R840 Gebruikershandleiding - Pagina 25

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Dell EMC VxFlex Ready Node R840. Dell EMC VxFlex Ready Node R840 44 pagina's.

Dell EMC VxFlex Ready Node R840 Gebruikershandleiding
Table 16 Operating temperature derating specification (continued)
Operating temperature derating
40–45 °C (104 °F–113 °F)

Standard operating temperature

The standard operating temperature for altitude less than 950 m or 3117 ft ranges 10 °C–35°C with no direct sunlight
on the equipment.
Note:
The 2.5-inch hard drive chassis supports a maximum of 145 W processors.
Table 17 Standard operating temperature specifications
Standard operating temperature
Continuous operation (for altitude less than 950 m or
3117 ft)

Expanded operating temperature

When the system is in continuous operation, the expanded operating temperature ranges 5 °C–40°C at 5% to 85% RH
with 29°C dew point. NOTE: Outside the standard operating temperature (10 °C–35°C), the system can operate
continuously in temperatures as low as 5°C and as high as 40°C. For temperatures 35 °C – 40°C, derate maximum
allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). When the system is operating at < 1% of annual
operating hours, the expanded operating temperature is –5 °C–45°C at 5% to 90% RH with 29°C dew point. NOTE:
Outside the standard operating temperature (10 °C–35°C), the system can operate down to –5°C or up to 45°C for a
maximum of 1% of its annual operating hours. For temperatures 40 °C–45°C, derate maximum allowable temperature
by 1°C per 125 m above 950 m (1°F per 228 ft).
Table 18 Expanded operating temperature specifications
Expanded operating temperature
Continuous operation
≤ 1% of annual operating hours
Note:
When operating in the expanded temperature range, the performance of the system may be impacted.
Specifications
Maximum temperature is reduced by 1°C/125 m (1°F/228 ft), above 950 m
(3,117 ft).
Specifications
10 °C–35°C (50 °F–95°F) with no direct sunlight on the equipment.
Specifications
5 °C–40°C at 5% to 85% RH with 29°C dew point.
Note:
Outside the standard operating temperature (10 °C–
35°C), the system can operate continuously in
temperatures as low as 5°C and as high as 40°C.
For temperatures 35 °C – 40°C, derate maximum allowable
temperature by 1°C per 175 m (1°F per 319 ft.) above 950 m
(3,1171 ft.).
–5 °C–45°C at 5% to 90% RH with 29°C dew point.
Note:
Outside the standard operating temperature (10 °C–
35°C), the system can operate down to –5°C or up to 45°C
for a maximum of 1% of its annual operating hours.
For temperatures 40 °C – 45°C, derate maximum allowable
temperature by 1°C per 125 m (1°F per 228 ft.) above 950 m
(3.117 ft.).
Technical specifications
R840xd Owner's Guide
25