Installation
^ Secure the front of the appliance to
the floor of the housing unit from
below using 4 screws (6 screws for
90 cm wide cooker hood).
To avoid damaging the deflector plate
when it is pulled out, care should be
taken to screw the fixing screws in
straight, and to ensure that the
screwheads are countersunk.
^ Secure the spacer strip to the back of
the appliance from behind using
4 plastic rivets as shown.
28
Attaching the lightshield
^ Attach the lightshield (if using).
A DML 300 installation kit, available as
an optional accessory, is required for
this.
This installation kit is supplied with the
DFB lightshield.
Follow the installation instructions
supplied.
Weight of a lightshield matching
existing furniture
The lightshield must not exceed 1300 g
in weight.
This applies to lightshields with a depth
of up to 30 mm.
For larger or heavier lightshields, the
weight must be reduced by e.g.
machining it away at the back.