Miele TX2070 Bedienings- en installatie-instructies - Pagina 31

Blader online of download pdf Bedienings- en installatie-instructies voor {categorie_naam} Miele TX2070. Miele TX2070 44 pagina's.

a 3 protective sheets
for use when fitting the tower.
b Upper wall bracket
for securing the extension piece.
c Middle wall bracket
for securing the extension piece.
d 1 exhaust socket
for exhaust ducting  150 mm.
e 1 reducing collar
for exhaust ducting  125 mm.
f 1 non-return flap
for fitting into the exhaust connec-
tion on the motor unit (not needed
for recirculation mode)
2 screws 5 x 60 mm and
2 plugs 8 x 50 mm
5 screws 5 x 60 mm and
5 plugs 8 x 50 mm
for securing the brackets and the appli-
ance unit to the wall.
The screws and plugs are designed
for use in solid walls only.
For other types of wall construction,
alternative fixings will be required.
Make sure the wall is able to take the
weight of the cooker hood.
6 screws 3.5 x 9.5 mm
for securing the canopy and filter hous-
ing
2 cover caps
1 lever
for changing the halogen lamps and
dismantling the tower
Installation instructions
Installation
31