Preparations

When installing the camera on a wall or a ceiling, there are four methods as specified below.
(☞ Pages 20 and 21).
• Using the two-gang junction box
• Installing the camera directly on the ceiling or wall
• Using the optional ceiling mount bracket WV-Q168 (for embedded installation on a ceiling)
• Using the optional ceiling mount bracket WV-Q105*
Important:
• Procure 4 screws (M4) to secure the camera to a wall or a ceiling according to the material of
the installation area. In this case, wood screws and nails should not be used. For mounting a
camera on a concrete wall, use an anchor bolt (for M4) or an AY plug bolt (M4) for securing.
(Recommended tightening torque: 1.6 N·m {1.18 lbf·ft})
• Required pull-out capacity of a single screw/bolt is 196 N {44 lbf} or more.
• If a ceiling board such as plaster board is too weak to support the total weight, the area shall
be sufficiently reinforced or the optional ceiling mount bracket for the camera, WV-Q105, must
be used.
The mounting conditions of the camera are described as follows:
Installation
Applicable mount
place
bracket
Ceiling/wall
Two-gang junction
box
Ceiling/wall
(Direct mounting)
Ceiling
WV-Q168 (approx.
280 g {0.8 lbs})
Ceiling
WV-Q105*
150 g {0.8 lbs})
*1 PAL models only
*2 Make sure that the installed mount bracket can support more than 5 times of the weight of the
camera.
Recommended
screw
M4
M4
1
(approx.
1
(for direct mounting on a ceiling)
Number of
screw
4 pcs.
4 pcs.
Minimum pull-out
strength (per 1 pc.)
196 N {44 lbf}
196 N {44 lbf}
2
*
2
*
19