D. WINTERIZING PROCEDURES

2. HARD-FREEZE CONDITIONS
(Air temperature remains below 32ºf for more than 4-hours)
TO AVOID INJURY FROM ROTATING EQUIPMENT, DISCONNECT ELECTRICAL
POWER FROM HEAT PUMP BEFORE PROCEEDING WITH INTERNAL DRAIN
WINTERIZING PROCESS. FAILURE TO HEED THE FOLLOWING MAY RESULT
1. Disconnect all electrical power to the heater; turn off circulating pump.
2. At the two (2) connection unions, disconnect the plumbing to the heater (removal is
counterclockwise).
3. Locate the drain plug at outside, lower front of heater. (see figure 1)
If the unit does not have an external drain plug, remove the exterior front panel of the unit.The
internal drain plug is located at the base of the heat exchanger (see figure 2). Follow the same
procedure as with an external drain plug.
4. Using a 5/8", box-end wrench, remove the drain plug (removal is Counterclockwise).
5. Permit all water to drain from the condenser and then replace the plug: thread the plug in
clockwise until just snug, then apply an additional 1/8 turn.
6. To prevent insects and vermin from entering the plumbing during the winterized period,
partially reconnect the two (2) plumbing connection unions: couple each union one or two
threads; this will permit condensation to drain, but will prevent most insects and animals from
entering the plumbing circuit.
7. Next season: to ready the heat pump for use, simply retighten plumbing connection unions.
Hand-tight is generally sufficient.
FIGURE 1
EXTERNAL
DRAIN PLUG
E. ELECTRICAL CONNECTIONS AND WIRING
MAKE SURE TO TURN OFF ALL POWER TO UNIT INCLUDING POWER
TO POOL PUMP TIMER PRIOR TO MAKING ANY ELECTRICAL CON-
NECTIONS. SPECIFICATIONS ARE SUBJECT TO CHANGE. ALWAYS
REFER TO WIRING DIAGRAM LOCATED ON THE BACK OF THE UNIT'S
PLASTIC FRONT COVER AND DATA PLATE ON LEFT SIDE OF PLASTIC
FRONT PANEL.

1. SUPPLY WIRING 220V

• Remove plastic front panel from unit.
• Locate and remove electric box high voltage cover located on left side of electric box.
• Determine sealtight length and slip plastic adaptor over conduit. Run conduit and proper
WARNING !
IN PERMANENT INJURY OR DEATH.
FIGURE 2
7
INTERNAL
DRAIN PLUG