aquatherm 50341 Bedienings- en onderhoudshandleiding - Pagina 2
Blader online of download pdf Bedienings- en onderhoudshandleiding voor {categorie_naam} aquatherm 50341. aquatherm 50341 8 pagina's. Fusion for aquatherm green pipe, aquatherm blue pipe, aquatherm lilac pipe, aquatherm red pipe and aquatherm ti pipesystems from 16 up to 125 mm
PART A: hEATINg UP PhAsE / hANDLINg
Temperature pilot lamp
(yellow)
glows constantly while the
heat-up phase and blinks, when the
welding temperature is achieved
Operating lamp
(green)
glows constantly, as soon as
the device is conntected with
the power supply system
Part A: heating up phase
7. During the heating up phase tighten the welding tools carefully with
the Allan key.
Take care that the tools completely contact the heating plate. Never
use pliers or any other unsuitable tools, as this will damage the coating
of the welding tools.
8. The temperature of 260° C is required for the welding of aquatherm
PP-R pipes.
Acc. to DVS - Welding Guidelines the temperature of the welding
device has to be checked at its tool before starting the welding process.
This can be done with a fast indicating surface thermometer.
ATTENTION:
First welding - soonest 5 minutes after reaching of the welding
temperature. DVS 2207, Part 11.
Part A: handling
9. A tool change on a heated device requires another check of the welding
temperature at the new tool (after its heating up).
10. If the device has been unplugged, e.g. during longer breaks, the heating
up process, has to be restarted (see item 6).
11. After use unplug the welding device and let it cool down. Water must
never be used to cool the welding device, as this would destroy the
heating resistances.
12. Protect aquatherm- welding devices and tools against impurities. Burnt
particles may lead to an incorrect fusion. The tools may be cleaned with
aquatherm cleaning cloths, Art.-No. 50193.
Always keep the welding tools dry.
handle
heating plate
welding tools
13. After welding, do not lay the the device on the Teflon coated tool, but
put it down in the provided supporting stand.
14. For a perfect fusion, damaged or dirty welding tools must be replaced,
as only impeccable tools guarantee a perfect connection.
15. Never attempt to open or repair a defective device. Return the defective
device for repair.
16. Check the operating temperature of aquatherm- welding devices
regularly by means of suitable measuring instruments.