Axor Uno 45134009 Gebruiksaanwijzing/montagehandleiding - Pagina 2
Blader online of download pdf Gebruiksaanwijzing/montagehandleiding voor {categorie_naam} Axor Uno 45134009. Axor Uno 45134009 16 pagina's.
EN
0 2
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
⁄ The drain valve must only be used as intended. It is not
allowed to attach other objects to the drain valve, for
example a semi-pedestal.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
D I M E N S I O N S (see page 08)
F L O W D I A G R A M (see page 08)
S P A R E P A R T S (see page 10)
S P E C I A L A C C E S S O R I E S
(order as an extra)
⁄ special tool #58085000 (see page 06)
⁄ Installation putty (see page 07)
C L E A N I N G (see page 13)
A S S E M B L Y (see page 12)
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C / 4 min
O P E R A T I O N (see page 12)
Hansgrohe recommends not to use as drinking
water the first half liter of water drawn in the
morning or after a prolonged period of non-use.