Architectural Area Lighting MicroCore Installatiehandleiding - Pagina 5

Blader online of download pdf Installatiehandleiding voor {categorie_naam} Architectural Area Lighting MicroCore. Architectural Area Lighting MicroCore 7 pagina's.

17760 ROWLAND ST.
CITY OF INDUSTRY
CALIFORNIA 91748
www.aal.net
MicroCore Upgrade Kit Installation Guide
Fixture: Universe Collection Medium (UCM) (HID to LED)
A56414-12
SPCR-3/8inODx .049in x5.058in
A84119
BOLT-1/4-20x6 HEX HD SS
NOTE: WITH UPLIGHT OPTIONS, REPLACE THE CURRENT
STANDOFFS BY PROVIDED ONES (AS SHOWN ABOVE) TO
ACCOMMODATE THE CHANGE IN HEIGHT OF NEW
COMPONENTS.
2. Connect green "C" to fixture ground lead "C" as shown in Fig.
7-2.
3. Connect flying driver assembly green lead "D" to fixture
ground "D" as shown in Fig. 6-2.
93046644 REV. D
Tel(626)968-5666
Fax(626)968-5716
TM
D
FIG. 5-3
FIG. 6-2
A R C H I T E C T U R A L
6.
WIRE CONNECTIONS TO DRIVER ASSEMBLY
C
C
B
A
CONNECTION TO LED
MICROCORE
ASSEMBLY
!
1. Connect incoming black "A" and incoming white "B" to driver
assembly black "A" and white "B" as shown in Fig. 6-1 & Fig.
6-2
Note: no change in grounding.
7.
C
ASSEMBLE DRIVER ASSEMBLY
C
B
A
D
PAGE 5/7
A R E A
L I G H T I N G
BLACK
A
C
GREEN (GROUND TO
BALLAST PLATE)
NOTE: SEE WIRING DIAGRAM
SCR-8-32x3/4 PHH PHMS SS
1. Assemble driver assembly to the dome by (2) provided 8-32
3/4" screws as shown in Fig 7-1.
WHITE
B
CONNECTION TO
INCOMING POWER
D
FIG. 6-1
2X A84024
FIG. 7-1