SENC 150
Encoder orientation ...
Machine
cross feed
Machine
base
These instructions will guide you through installing
the encoder as shown in this view.
Cable exit ...
Plug
Cover plate
T-10 Torx screw (2)
Determine the cable exit direction before installing
the encoder.
To change the cable exit direction; remove the cover
plate and rotate the cable 180°.
Spar installation ...
.56
Locate the spar mounting hole using the
dimensions shown.
Drill and tap for a 1/4-20 x 1/2" deep.
P.N. 385076.130 Ed B 2/06
Viewed from the front
of the grinder
Spar
Encoder Assembly
flush surfaces this side
(side 1 & 2)
Reading head
mounting bracket
Vinyl cable grommet
Armor cable hex crimp
13.93"
Mounting hole
Installation Manual 385076-000
Encoder Installation Manual For: Chevalier FSG-2A 1224
Surface Grinder: Cross Feed "X" Axis
CROSS
FEED TRAVEL
1/4-20 x 1/2" BHCS
Fasten the spar at one end, and align the top
surface to the cross feed travel.
Transfer punch the other end mounting hole.
Drill and tap location for a 1/4-20 x 1/2" deep.
1/4-20 x 1/2" BHCS (2)
Attach the spar to the cross feed.
Viewed from the
back side
Front
surface
Front surface
to be parallel
to the carriage
within .010"
Align the front surface of the spar, shim if required
between the spar and machine if necessary.
Align the top surface of the spar as done previously to
within .010" TIR to the cross feed travel.
Secure spar in place maintaining alignment.
2
Align the top of spar
to within .010" TIR
Transfer punch location
* Flat washer .017" thk. (2)
travel to
Acu-Rite Companies Inc.