ACU-RITE SENC 150 Installatiehandleiding - Pagina 2
Blader online of download pdf Installatiehandleiding voor {categorie_naam} ACU-RITE SENC 150. ACU-RITE SENC 150 4 pagina's. Chevalier fsg-2a 1224 surface grinder cross feed “x” axis
Ook voor ACU-RITE SENC 150: Installatiehandleiding (8 pagina's), Referentiehandleiding (20 pagina's), Installatiehandleiding (6 pagina's), Gebruiksaanwijzing (12 pagina's)
SENC 150
Encoder orientation ...
Machine
cross feed
Machine
base
•
These instructions will guide you through installing
the encoder as shown in this view.
Cable exit ...
Plug
Cover plate
T-10 Torx screw (2)
•
Determine the cable exit direction before installing
the encoder.
•
To change the cable exit direction; remove the cover
plate and rotate the cable 180°.
Spar installation ...
.56
•
Locate the spar mounting hole using the
dimensions shown.
•
Drill and tap for a 1/4-20 x 1/2" deep.
P.N. 385076.130 Ed B 2/06
Viewed from the front
of the grinder
Spar
Encoder Assembly
flush surfaces this side
(side 1 & 2)
Reading head
mounting bracket
Vinyl cable grommet
Armor cable hex crimp
13.93"
Mounting hole
Installation Manual 385076-000
Encoder Installation Manual For: Chevalier FSG-2A 1224
Surface Grinder: Cross Feed "X" Axis
CROSS
FEED TRAVEL
1/4-20 x 1/2" BHCS
•
Fasten the spar at one end, and align the top
surface to the cross feed travel.
•
Transfer punch the other end mounting hole.
•
Drill and tap location for a 1/4-20 x 1/2" deep.
1/4-20 x 1/2" BHCS (2)
•
Attach the spar to the cross feed.
Viewed from the
back side
Front
surface
Front surface
to be parallel
to the carriage
within .010"
•
Align the front surface of the spar, shim if required
between the spar and machine if necessary.
•
Align the top surface of the spar as done previously to
within .010" TIR to the cross feed travel.
•
Secure spar in place maintaining alignment.
2
Align the top of spar
to within .010" TIR
Transfer punch location
* Flat washer .017" thk. (2)
travel to
Acu-Rite Companies Inc.