LEDs
The LED indicators (see
status of the network link, the overall health of the blade server, and whether the server is set to give a
flashing blue beaconing indication.
The removable hard disks also have LEDs indicating hard disk access activity and hard disk health.
Table 1
LED
Buttons
The Reset button is just inside the chassis and must be pressed using the tip of a paper clip or a similar
item. Hold the button down for five seconds and then release it to restart the server if other methods of
restarting are not working.
The beaconing function for an individual server may be turned on or off by pressing the combination
button and LED. See
can also be turned off and on from there.
The power button and LED allows you to manually take a server temporarily out of service but leave it
in a state where it can be restarted quickly, or to bring it back into service. If the desired power state for
a service profile associated with a blade server or an integrated rack-mount server is set to "off", using
the power button or Cisco UCS Manager to reset the server will cause the desired power state of the
server to become out of sync with the actual power state and the server may unexpected shutdown at a
later time. To safely reboot a server from a power-down state, use the Boot Server action in Cisco UCS
Manager.
Cisco UCS B250 Extended Memory Blade Server Installation and Service Note
2
Table
1) indicate whether the blade server is in active or standby mode, the
Blade Server LEDs
Color
Power
Off
Green
Amber
Link
Off
Green
Health
Off
Green
Amber
Blinking
Amber
Beaconing
Off
Blinking
blue 1 Hz
Activity
Off
(Disk Drive)
Green
Health
Off
(Disk Drive)
Amber
Table 1
for details. Beaconing will be reflected in the UCS Manager interface and
Description
Power off
Normal operation
Standby
None of the network links are up
At least one network link is up
Power off
Normal operation
Minor error
Critical error
Beaconing not enabled.
Beaconing to locate a selected blade—If the LED is not
blinking, the blade is not selected. You can initiate
beaconing in UCS Manager or with the button.
Inactive.
Outstanding I/O to disk drive
No fault
Some fault
OL-22474-03