Alderlea T5 Installatie- en bedieningshandleiding - Pagina 10
Blader online of download pdf Installatie- en bedieningshandleiding voor {categorie_naam} Alderlea T5. Alderlea T5 20 pagina's.
Installation Procedure – Mobile Home
CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL
AND CEILING/ROOF MUST BE MAINTAINED.
Note: See "Combustion Air" section on page 11
1.
Position stove and fl oor protection with hole for combustion air in accordance with the
clearances as stated on the label and in Figure #3.
2. Mark the position for the hole in the ceiling and roof by using a string and plumb-bob.
3. Check that the intended location will not interfere with fl oor joists, ceiling joists or rafters
before proceeding further.
4. Cut a hole in the ceiling and roof to suit the chimney system and frame in the sides. The
chimney support is mounted to the framing.
5. Assemble chimney sections so the fi nished length is resting on the support and protruding
through the roof. Avoid having joints between ceiling and roof. Install radiation shield.
Assemble fl ashing and storm collar and be sure to maintain the vapour barrier at this
point. (Seal securely.) Attach rain cap and check fl ashing for leaks.
5. Install connector as per manufacturer's instructions.
6. To attach stove to fl oor, fi rst remove the leveling bolts from the legs. Then attach stove
to fl ooring using two 1/4" x 2" or longer lag screws through the leveling bolt holes.
10
Follow chimney and chimney
components manufacturer's
instruction for assembly and
installation.
020512-20 ALT5