Aros NetMan 204 Solar Snelle referentie installatiehandleiding - Pagina 4
Blader online of download pdf Snelle referentie installatiehandleiding voor {categorie_naam} Aros NetMan 204 Solar. Aros NetMan 204 Solar 4 pagina's.
Micro-USB port
NetMan 204 Solar doesn't currently use the Micro-USB port.
Serial port
NetMan 204 Solar makes available a serial communication port to which you can
connect a RS-485/Modbus power meter for special functions.
Led
This led describes the status of NetMan 204 Solar:
SOLID RED: NetMan 204 Solar is not communicating with the inverter.
FLASHING RED: the board is currently updating software.
OFF: regular working.
Reset button
The reset button allows to reboot the NetMan 204 Solar.
To reset NetMan 204 Solar: keep press the reset button until the red led start
flashing (ca. 2 seconds) and then release it.
U
SERS
It is possible to access to NetMan 204 Solar with the following users:
Username
Default password Privileges
ftpuser
arosftp
CONFIGURATION
NetMan 204 Solar can be configured using SirioDataControl software; this
software can be downloaded from www.aros-solar.com.
NetMan 204 Solar comes provided as factory default with the following
network configuration:
IP address: 192.168.1.200
Netmask:
255.255.255.0
Gateway:
192.168.1.254
NetMan 204 needs approximately 1 minute to become operational from
when it is powered up or after a reboot; before this time the device may
not be configurable.
In order to change the configuration of NetMan 204 Solar, please verify that the
Netman 204 Solar is connected to a network and run the SirioDataControl software
on a Pc or Mac on the same network. Please refer to the complete user manual.
The complete user manual can be downloaded from:
http://www.aros-solar.com
0MNPVXXXXXXX
This is the ftp user that can access the log files
(see SirioDataControl software)
5
7
INSTALLATION
Remove the cover of the inverter expansion slot by removing the two retaining
screws.
Insert NetMan 204 Solar in the slot.
Secure Netman 204 Solar to the slot using the two screws removed previously.
J
UMPER SETTING
Jumper JP4 have to be open only when NetMan 204 Solar is installed in
SIRIO EVO 10000 (p/n 6PVE10KA) and SIRIO EVO 12500 (p/n
6PVE12KA); for all the others models, JP4 has to be closed.
JUMPER SETTING for SIRIO EVO 10000 and SIRIO EVO 12500
JUMPER SETTING for all the other models
6