Akron DECKMASTER 3440 Installatie-, bedienings- en onderhoudsinstructies - Pagina 8

Blader online of download pdf Installatie-, bedienings- en onderhoudsinstructies voor {categorie_naam} Akron DECKMASTER 3440. Akron DECKMASTER 3440 15 pagina's. Electric monitor for standard configuration with potentiometers & u2 logic box

Nozzle Installation

The nozzle should be threaded onto the outlet of the monitor. Place the pattern actuator in a position that does not
stretch the power cord, and then tighten the swivel. Verify that the actuator orientation does not interfere with

the monitor.

Controller Box Installation

This monitor is used with a 6032 Universal II Controller. It normally mounts on or below the deck and must be mounted
close enough to the monitor so that the 10 foot cable of the monitor wiring harness has sufficient slack to allow the
monitor to travel through its full rotational range. Refer to the "6032 Universal II Controller Installation, Operation &
Maintenance Manual" (part number 122552) as a guide.
Do not extend the monitor wiring harness.

Electrical Installation Instructions

Make the I/O and power connections to the 6032 controller and then plug the monitor harness into the controller. Refer
to the "6032 Universal II Controller Installation, Operation & Maintenance Manual" (part number 122552) as a guide
Contact Position
1
Power In – Vehicle Battery (+12/24 VDC)
2
Power In – Vehicle Battery (−)
3
Power In – Auxiliary Battery (+12/24 VDC)
4
Power In – Auxiliary Battery (−)
5
Output – H-Bridge #5A
6
Output – H-Bridge #5B
7
Output – Logic #1
8
Output – Logic #2
9
Output – Logic #3
10
Output – Bi-stable Relay Common
11
Output – Bi-stable Relay N.O.
12
Output – Bi-stable Relay N.C.
13
Input – Switch #1 (System Enable)
14
Input – Switch #2
15
Input – Switch #3
16
Input – Switch #4
17
Input – Switch #5
18
Input – Switch #6
19
Input – Switch #7
20
Input – Switch #8
21
Input – Switch #9
22
Power Out – Peripheral (+12/24 VDC)
23
Data – J1939 CAN High (+)
24
Data – J1939 CAN Low (−)
25
Power Out – Peripheral (−)
26
Data – Proprietary CAN High (+) (Unused)
27
Data – Proprietary CAN Low (−) (Unused)
28
Data – V-Mux Com A (+) (Unused)
29
Data – V-Mux Com B (−) (Unused)
Harness 721582 for Power & Signal Connector J1 on Controller
Function
Table 1 – Power & Signal Harness Connections
Comments
(Optional)
(Optional)
Panel LED
Discharge
+ Right / Left -
+ Up / Down -
+ Stream / Fog -
+ Valve Open / Close -
+ Gallonage High / Gallonage Low -
+ Oscillate Set / Pause -
+ Deploy / Stow -
+ Aux Agent 2 / Aux Agent 1 -
Powers the System Enable (#13)
Page 8
Wire Color & Size
Red – 12 AWG
Black – 12 AWG
Green – 12 AWG
Black – 12 AWG
Red – 16 AWG
Black – 16 AWG
Brown – 16 AWG
Red – 16 AWG
Orange – 16 AWG
Yellow – 16 AWG
Green – 16 AWG
Blue – 16 AWG
Brown – 18 AWG
Red – 18 AWG
Orange – 18 AWG
Yellow – 18 AWG
Green – 18 AWG
Blue – 18 AWG
Violet – 18 AWG
Gray – 18 AWG
White – 18 AWG
Brown – 18 AWG
Yellow – 18 AWG
Green – 18 AWG
Drain – 18 AWG
Sealing Plug
Sealing Plug
Sealing Plug
Sealing Plug