NOTE
Unless the projector is operated in a very dusty environment, the vents should not need cleaning. However, when
mounting the projector, make sure to allow at least six inches of space between the vents and any walls. Also, it is
very important that the exhaust air is separate from the intake air. Don't put the whole projector in a big box
without channeling the two away from each other.
What is the expected life of the lamp?
The lamp life is approximately 2,000 hours. When the lamp timer reaches 2,000 hours, the Alarm LED on the projector will
light red, indicating that it is time to replace the lamp. This is a good time to replace the lamp and reset the lamp timer.
NOTE
The expected lamp life is an approximation provide by the lamp manufacturer. Actual lamp life may vary depending
on lamp usage, maintenance and manufacturing.
How do I determine the number of lamp hours used?
Press the Menu button, then navigate to Basic > Advanced > Service. Select Info. The number of lamp hours appears in the
Service Info window.
How do I reset the lamp timer?
In the menu of the projector, navigate to Basic > Advanced > Service. Select the Reset Lamp Timer option, and press the
Select button. When the Lamp Change window appears, click Select again to reset the timer. You can do this prior to 2,000
hours.
NOTE
You must have a source hooked up to the projector when resetting the lamp timer. If you don't, the Reset Lamp
Timer setting is dimmed.