Be sure to secure the ducting with tie wrap. Also, keep in mind, that the supply ducting can be screwed
into an adapter if necessary.
Ducting Installation
••
Maximum total length of duct run= 10'
•
• Maximum length if only ducting inlet or outlet= 6'
•
• To connect 12" return ducting, it may be helpful to:
•
1. Remove inlet grille from end cap
•
2. Connect duct to inlet grille
•
3. Reconnect inlet grille to end cap
•
Note: The supply duct adapter is standard on all units.
6.
7.
Removing Duct Adapter
If it is necessary to remove the
adapter, place hand at bottom of
adapter and use your fingers to press
up on base of adapter. Next, lift hooks
out of cover holes, and remove
adapter from machine.
Flex Duct Installation
Rotate the flex duct counter-
clockwise or simply position
over adapter and secure with
wire tie.
•
a.
10
Installing Duct Adapter
To install adapter, line up with
holes on the side of unit and
push up from base of adapter.
Flex Duct Removal
Rotate flex duct clockwise or
remove wire tie and slide duct
off adapter.