Figure 13 - Chimney Supports
FIRESTOP SPACERS (FS-8DM)
Firestop spacers are required at each point where the chimney pen-
etrates a floor or ceiling joist space. Their purpose is to establish
and maintain the required clearance between the chimney and the
combustible materials.
When the pipe passes through a framed opening into a living space
above, the firestop must be placed onto the ceiling from below as
shown in Figure 14. When the pipe passes through a framed opening
into an attic space above, the firestop must be placed on the attic
floor as shown in Figure 15.
126647-01A
VENTING INSTALLATION Continued
Return
Elbow
Offset
Elbow
Return
Elbow
Offset
Offset
Elbow
Elbow
A
Figure 12 - Typical Offset Installations
See
DETAIL A
See
DETAIL B
www.Astria.US.com
Return
Elbow
Ceiling
Support Pipe
12S-8DM
6' Max.
Offset
Elbow
6' Max.
B
Firestop Spacer
Figure 14 - Firestop Spacer with Living Space Above Ceiling
Firestop
Spacer
Figure 15 - Firestop Spacer with Attic Space Above Ceiling
Return
Elbow
6' Max.
6' Max.
C
Existing
Ceiling Frame
Screws or Staples
(Min. of 8)
Screws or Staples
(Min. of 8)
Existing
Ceiling Frame
9