Press and hold small button: Turn on relay 2 (connect B and C, disconnect A and B)
Release small button: Turn off relay 2 (disconnect B and C, connect A and B)
Setting control mode Latched: Disconnect Jumper-1 and Jumper-2.
Control mode Latched: Press -> On, another relay Off; Press another button -> Off.
Press big button: Turn on relay 1 (connect B and C, disconnect A and B)
Turn off relay 2 (disconnect B and C, connect A and B)
Press small button: Turn on relay 2 (connect B and C, disconnect A and B)
Turn off relay 1 (disconnect B and C, connect A and B)
Setting control mode Momentary + Toggle: Connect Jumper-1 and Jumper-2.
Control mode Momentary (Channel 1): Press -> On; Press again -> Off.
Press and hold big button: Turn on relay 1 (connect B and C, disconnect A and B)
Release big button: Turn off relay 1 (disconnect B and C, connect A and B)
Control mode Toggle (Channel 2): Press and hold -> On; Release -> Off.
Press small button: Turn on relay 2 (connect B and C, disconnect A and B)
Press small button again: Turn off relay 2 (disconnect B and C, connect A and B)
We have learned remote control to the receiver. If you don't want the receiver to work with the remote control, you can delete all codes of remote
controls, which are stored in the receiver.
Operation: Press and hold the button of receiver until signal LED flashes slowly; release the button, LED keeps slow flash. That means all stored
codes have been deleted successfully.
Learning the button of remote control:
1) Press the button of receiver; signal LED on the receiver keeps shining. The receiver enters into status of LEARNING.
2) Press any one button on remote control. If signal LED flashes quickly 15 times and turns off, it means learning is successful.
3) When receiver is in the status of LEARNING, press again the button of receiver, signal LED turns off, learning process will be discontinued.
4) The receiver can learn several remote controls with different codes.
Application Circuit
Signal LED
IC
Power LED
Relay 2
C
B
A
Lamp 2
DC0~28V / AC110~240V
A, B=Normally Closed; B, C=Normally Open.
Button
Antenna
Relay 1
_
+
C
B
A
Lamp 1
Power supply
SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD
Http://www.caymart.com
Application: For DC12V motor or lamp
Signal LED
IC
Power LED
Relay 2
C
B
A
+
M
Motor 2
Button
Antenna
Relay 1
_
+
C
B
A
+
M
Motor 1
_
+
Power supply