Baumer VeriSens CS Series Skrócona instrukcja obsługi - Strona 13
Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Akcesoria Baumer VeriSens CS Series. Baumer VeriSens CS Series 44 stron.
ATTENTION!
Incorrect voltage will destroy the device: Pin 1: Power (+18...30 VDC)
Electrical connection
1: PWR (+18...30 VDC) Brown
2: Ground
Blue
White
3: IN1 (Trigger)
4: OUT1
Green
5: IN2
Pink
6: OUT2
Yellow
The duration of the output signals and the time of output are adjusted by software and
depend on the current job.
Ethernet connection
NOTE
To avoid network
malfunctions, ensure that
each IP address is unique
within your network!
1)
M12 / 12-pin
7
6
8
9
12
5
11
1
4
10
3
2
7: OUT3
8: IN3
9: OUT4 / RS485+ Red
10: IN4
11: IN5
12: OUT5 / RS485- Red-Blue
Start the Application Suite . The VeriSens
must be connected to the same network. By default, the
use of DHCP is enabled. If a DHCP server is not found
within 15 seconds, the following network configuration
is used:
IP address:
Subnet mask:
For more information, please see page 18.
Pin 2: Ground
Ethernet
1)
M12 / 4-pin
3
4
2
1
Black
1: TD+
Gray
2: RD+
3: TD-
Violet
4: RD-
Gray-Pink
on device
1)
voltage outputs configurable by software
2)
192.168.0.250
255.255.255.0
English
Electr. connection illumination
M8 / 4-pin (XC only)
1
3
2
4
1: +24 V or +48 V Flash
2: +12 V or +24 V Flash
3: Ground
4: Flash Sync
®
and your PC
1)
2)
EN
EN
13 13