ELECTRICAL CONNECTION / OUTPUTS HMCP16
6.8.2.7
Output 1 (or 2) „P": Universal HTL/TTL + error output TTL level
Flange connector M23, 12-polig, male contacts, counter-clockwise
There is an inverted error signal via pin 7 available� In case of failure it has
an output of 0 V� In failure-free operation pin 7 have a ~5 V (RS422) TTL level
compared to pin 9�
6.8.2.8
Output 1 (or 2) „M": 2x SSI
Flange connector M23, 12-polig, male contacts, counter-clockwise
i
Depending on the version
2)
Only for power supply version „A" or „B"
9)
22/40
Only one SSI output is possible�
Pin
Assignment
1
B–
2
dnu
3
dnu / R+
2)
4
dnu / R–
2)
5
A+
6
A–
7
nE (TTL)
8
B+
9
0 V (nE)
10
0 V
11
dnu
12
+UB (5 VDC = TTL)
(10���30 VDC = HTL)
Pin
Assignment
1
SSI1 DA–
2
dnu
3
SSI2 CL+
4
SSI2 CL–
5
SSI1 CL+
6
SSI1 CL–
7
SSI2 DA+
8
SSI1 DA+
9
SSI2 DA–
10
0 V
11
dnu
12
dnu / +UB
9)
MB168T1EN - 11184527, 19A2, Baumer_HMC16-T1_II_EN