MOUNTING
4.3
Maximum permissible mounting tolerance when the Baumer Hübner K 35 spring
disk coupling is used
Devices with a solid shaft should be driven through the Baumer Hübner K 35 spring disk
coupling (accessory), that can be pushed onto the shaft without axial loading�
i
The figure below shows the device with EURO flange B10, the same maximum
permissible mounting tolerances are valid with housing foot B3�
)
The device must be mounted on the drive with the least possible angular error and
parallel misalignment�
)
Risk of damaging the ball bearings
Coupling components must not be driven onto the shaft with improper force (e� g�
hammer impacts), because of the risk of damaging the ball bearings�
F
max
Admissible
parallel misalignment
* With insulated hub
All dimensions in millimeters, unless otherwise stated�
11/29
= 10 N
2-10
Admissible
angular error
MB245EN - 11171693, 19A3, Baumer_PMG10-SSI_II_EN
Admissible
axial movement
±0.7 (±0.3*)