TECHNICAL SPECIFICATION

Flow Range: 20-80L/min
Min Tested Flow Rate: 5L
Accuracy: The max error of dispenser volume is less than ±0.30%, its repeatability error
is less than 0.15%.
Noise Standard: <80dB(A Class)
Unit Price Range: 0.01-999.99
Volume Range: 0.01-999999.99
Amount Range: 0.01-9999999999.99
Environment condition: 1) Humidity:-30°C~+45°C
The max work ing pressure: <0.3MPa
Memory capacity : >128kB
Power: DC12V, DC24V,AC220V,AC380V
Communication Protocol: RS485

Working Principle

External Power
Take up the automatic nozzle, the signal will be transmitted to the main board. The main
board will transmit the operation signal to driver board, then open the solenoid
_
2) Relative humidity:<95%
_
_
Main board
Power planes
Flow meter
_
Display board
Encoder
Solenoid valve
(optional)
FILTER
Pressure oil
Key board
Nozzle Switch I
NOZZLE
Oil container