Andco Eagle Instrukcja instalacji

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Kontroler Andco Eagle. Andco Eagle 12 stron.

Andco Eagle Instrukcja instalacji
GE Oil & Gas
Andco Eagle Actuator
Installation Manual
NOTICE
The information contained in this manual is essential
to safe, successful, long term operation of your Andco
Eagle linear actuator. Read and follow the requirements
concerning storage, installation and adjustments. Failure
to do so could void the warranty covering your actuator.
This manual gives instructions for storing, installing,
operating and servicing the Model 3100 Eagle linear actuator.
Refer all questions not covered in this manual to:
GE Oil & Gas
16240 Port Northwest Drive
Houston, Texas 77041
Tel: 832-590-2306
Fax: 713-849-2879
Be sure to include the model and serial number
located on the nameplate of your Eagle actuator in all
communications and parts orders. The nameplate is
located on the gear housing cover.
Intent of Usage
The Andco Eagle Linear Actuator is a completely self-
contained electro-mechanical device. Its compact design
is equivalent in size to hydraulic or pneumatic cylinders.
Designed and fabricated for easy installation and
dependable long-life operation.
North American Sales Company - Serving Customers in California & Nevada - [email protected] - 310-459-8430
WARNING
PPE
Approved Personnel Protective
Equipment for the site must
be worn.
WARNING
GROUNDING LUG
Unit must be grounded with
minimum size 10 AWG wire.
These actuators feature:
• High-starting torque motor
with thermal overload protection
• Non-rotating extension rod
• Non-back driving acme screw
• All metal gearing
1.0 Storage Requirements
1.
Actuators should always be stored in a clean dry
environment, in a location where mechanical
damage to the actuator can't accidentally occur.
2.
All covers must remain in place and securely
fastened.
3.
All pipe plugs must remain in place and be kept tight.
4.
Actuators equipped with controllers can be
damaged by excessive moisture. Units so equipped
should be stored in a controlled environment
prior to installation. If the units are equipped
with compartment heaters, the heaters must be
continuously energized while in storage.
1.1 Lifting Instructions
1.
Do not lift Eagle actuator by limit switch
compartment.
2.
Follow applicable safety guidelines when lifting or
moving actuator.
2.0 Mounting Arrangements
NOTICE
While it is possible to mount the actuator in any position, it is not
recommended that the control compartment cover be positioned
face down. In order to maximize seal integrity, the unit should be
mounted with the extension rod pointed up (vertical installations) or
with motor on top (horizontal installations).
1.
The body tube adapter (57) is used for face flange or
trunnion-type mounting.
2.
The actuator can be clevis-mounted utilizing the clevis
(29) in the extension rod (6) and the rear clevis bracket,
located on the gear compartment cover (21).
Refer to Figure 1 on page 6.