DIP switch settings for A3101
The system can be expanded up to 4 entrance
panels and 32 internal monitors
The video module is configured by 6 DIP
switches.
The DIP switches can be modified either
before or after installation. Restarting the
camera module is necessary whenever the
DIP switches have been modified.
DIP switches 1 and 2 are for door station(s)
ID settings.
When multi door stations are installed on the
system, these two DIP switches must be set
correctly.
Door station DIP switch setting:
No.1 = 00 (Default setting)
No.2 = 10
No.3 = 01
No.4 = 11
DIP switch 3 needs to be set to 0 for
mechanical call button operation.
DIP switch 4 is for call button automatic
allocation. Call buttons are automatically
assigned to the indoor units. The default
setting for this DIP switch is 0
DIP switch 5 is for setting door unlock time. 0
is the default setting for one second delay and
1 is the setting for five seconds delay.
DIP switch 6 is for activating keys A and B
which are used for programming camera
module functions (see next section).
The default setting for this DIP switch is 0.
Video module functions and
programming
Restore factory settings
Warning:
All settings will be deleted if the Restore
Factory Setting is activated.
When the Camera Module is in standby, short
out the Exit Button Port (EB+, EB-) and toggle
DIP switch 6 four times. A long Beep will sound
and all three indicators will blink at the same
time meaning the Restore Factory Setting is
in progress.
Once the three Indicators turn off with a
warning sound of a long Beep, it means the
Restore Factory Setting is complete.
Activating touch keys, A and B
Key A and key B cannot be used on the
camera module until activated.
To activate the keys and set the unit to
programming mode, put DIP switch 6 to ON
position.
DIP switch 6 must be set to ON while the
others are set to OFF to program module.
When programming is finished, put DIP switch
6 back to OFF position to go back to standby.