Bose FreeSpace IZA 2120-HZ Instrukcja instalacji i obsługi - Strona 41
Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Wzmacniacz Bose FreeSpace IZA 2120-HZ. Bose FreeSpace IZA 2120-HZ 48 stron. Integrated / zone amplifiers
Również dla Bose FreeSpace IZA 2120-HZ: Instrukcja instalacji i obsługi (48 strony)
pro.Bose.com
ZA 2120-HZ specifications
Power Rating
Amplifier Power
Audio Performance
Frequency Response
THD+N
Channel Separation (Crosstalk)
Dynamic Range
Audio Inputs
Input Channels
Connectors
Input Range
Input Impedance
Maximum Input Level
Nominal Input Level
Audio Outputs
Outputs
Connectors
Nominal Output Level
Indicators and Controls
Power LED
Input Signal Clip LED
Output Signal Clip LED
Controls, Front Panel
Controls, Rear Panel
Electrical
Mains Voltage
AC Power Consumption
Mains Connector
Maximum Inrush Current
Overload Protection
Physical
Dimensions
Shipping Weight
Net Weight
Cooling System
General
Inputs (Control)
2 x 120 W @ 70/100V
55 Hz - 20 kHz (+0/–3 dB, @ 1 W reference 1 kHz)
≤ 0.3 % (at rated power)
≤ –58 dBu (below rated power, 1 kHz)
88 dB
1 unbalanced, 1 balanced
Stereo RCA, 5-pin Euroblock
–8 dBu to 22 dBu
20 kΩ
22 dBu
4 dBu
2
2-pin inverted Euroblock
2 x 120 W @ 70/100V
Solid blue indicates power is on, blinking blue indicates standby mode
Green indicates input signal is within –37 dBu to 11 dBu, red indicates signal is over 11 dBu
Green indicates output signal is within –46 dBFS to –2 dBFS, red indicates signal is over –2 dBFS,
approximately 80 W/channel, for each output 120 watts is 0 dBFS
Power On/Off
Auto Standby: On/Off switch, Input: Dual/Summed switch, Remote 1 Control: Zone 1/Zone 1+2 switch, Output
Voltage: 70/100V switch, Mute, Output trims, Remote (x2)
100 VAC - 240 VAC (±10%, 50/60 Hz)
23 W (Standby), 300 W (Max)
Standard IEC (C14)
12.6 Amps (230 VAC / 50 Hz), 7.8 Amps (120 VAC / 60 Hz)
High temperature, output short, excessively low or high AC line voltage
1.7" H x 19.0" W x 12.8" D (44 mm x 483 mm x 324 mm)
11.5 lb (5.2 kg)
8.5 lb (3.9 kg)
Single fan creates continuous left-to-right air flow
2 remote inputs for Volume Control (PC041966),
Mute input control via a normally open contact closure
Technical Information
English - 41