AOK ISF Series Instrukcja instalacji

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Oświetlenie zewnętrzne AOK ISF Series. AOK ISF Series 3 stron.

Installation Guide
This procedure is designed as an installation aid. Skilled tradespeople that are familiar with general construction and electrical
installation techniques should pe orm the installation. Licensed electricians should provide electrical installation connections.
Installations and connections should be done in accordance with all national and local codes and permits. In no way is this
document intended to construe warranty or fitness of use of the products described, nor is it intended to provide safety instruction
for those installing the product.
WARNING
Before proceeding with installation or service maintenance of this product.
• Disconnect power to reduce electrical shock risk.
• Review the entire Installation Guide.
• Inspect this properly packaged product for any damage that may have occurred during transit.
• Verify product application complies with manufacturer design recommendations.
• Verify the availability of necessary tools and incidental material.
• Verify applicable code requirements. Field assembly and installation are subject to acceptance by local inspection authority.
• Appropriate safety equipment to be determined by end user, per applicable safety standards and precautions.
Type-U Bracket Installation (Without visor)
1-1
The lamp cap rotates 360 degrees
1-3
Angle adjustment scale:
ISF Series Installation Guide
*Due to the constant improvements in product development, individual parameters might change. Please refer to our sales or R&D team for most up-to-date content as
specifications are subject to change without notice.
1-2
Tools:
10mm inner
hexagon wrench
M12 socket
hexagon screw
Safety rope
Torque of 142Nm
Ø416.0mm
Ø20.5mm
Ø13.0mm
Angle: 8°
50.0mm
Ø13.0mm
130.0mm
1-4 Braket with driver box
The first step:
1) Fix the angle of U bracket and fixture body, then adjust
the angle according to the result simulated by computer.
2) Use a special tool and a torque of 142Nm to fix the U
bracket and fixture body with 2 M12 inner hexagon screws,
as shown in Fig. (1), (2) and (3).
Fig. (1)
Fixture body
M12 screws
U bracket
Fig. (2)
Fig. (3)
Wiring Diagram
Positive (Fixture)
Negative (Fixture)
Ground
(Fixture)
SPD
External terminal
Input
The second step:
Use special tools to fix the U bracket and the plate with
driver box on the lamp pole with two M12 screws with a
torque of 142Nm, as shown in Fig (4), (5) and (6).
Fig. (4)
Fig. (5)
Fig. (6)
Conduit
Conduit
Driver
Output
+1 626-986-4050 (US)
+86 755 2357 9148 (CN)
@2022 AOK LED LIGHT CO., LTD. All Right Reserved.