Abus SHRM10000 Oryginalna instrukcja obsługi - Strona 14
Przeglądaj online lub pobierz pdf Oryginalna instrukcja obsługi dla Alarm dymowy Abus SHRM10000. Abus SHRM10000 16 stron. Z-wave smoke detector
5.4.
Reset (Factory-Reset)
5.5
Battery change
6. Advanced Z-Wave Parameter
6.1.
Association Group Information
Z-Wave devices can control other devices directly. This direct control is called in Z-
Wave association. For this purpose, the device ID of the device to be controlled must
be stored in the controlling devices. This is done in so-called association groups. An
association group is always linked to an event in the controlling device (pressing a key
or triggering a sensor). When this event occurs, a control command - usually a BASIC
SET - is sent to all devices stored in an association group.
The smoke detector supports the following association groups:
1. Remove the battery
2. Press the Network button and keep it
pressed while inserting the battery again.
3.
Device will restore factory settings
Note:
1, This procedure should only be used if the
primary gateway is not capable of acting.
2, If the multi-sensor is set to the factory
setting, the status is set to "not included", the
association
settings
configurations are reset to default.
1. Turn the device anticlockwise and
remove it from the mounting bracket and
remove the old battery
2. Insert a new battery, ensure that the
polarity is correct
3. Test the smoke alarm device. To do so,
press and release the test button. The
alarm will sound loud short beeps
indicating that the smoke detector works
normally
Turn the detector back onto the bracket
14
English
and
possible