Austa AU-1P20002G-230-EU Instrukcja instalacji i obsługi - Strona 10

Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Falownik Austa AU-1P20002G-230-EU. Austa AU-1P20002G-230-EU 13 stron.

8. SPECIFICATION

MODEL
Max Recommended PV Power (Wp)
Max DC Open Circuit Voltage (Vdc)
INPUT(DC)
Max DC Input Current (Adc)
MPPT Tracking Accuracy
MPPT Tracking Range(Vdc)
Max AC Output Power (Wac)
Nominal Power Grid Voltage (Vac)
Allowable Power Grid Voltage (Vac)
OUTPUT(AC)
Allowable Power Grid Frequency (Hz)
THD
Power Factor
SYSTEM
CEC Efficiency
EFFICIENCY
Night Time Tire Loss(W)
Over/Under Voltage Protection
Over/Under Frequency Protection
Anti-Islanding Protection
Over Current Protection
PROTECTION
Reverse DC Polarity Protection
FUNCTIONS
Overload Protection
Ground Fault Detection
Protection Degree
Environment Temperature
Display
OTHER
Communications
PARAMETERS
Dimension (D-W-H mm)
Weight(Kg)
(* Per IEEE 1547A)
14
AU-1P20002G-240-US AU-1P20002G-208-US
700x 4
700x 4
62
62
18*4
18*4
>99.9%
>99.9%
20-60
20-60
2000
2000
240
208
180-275
180-275(Adjustable
*
)
(Adjustable
*
)
55-65(Adjustable
)
55-65(Adjustable
)
*
*
<3%
<3%
(at rated power)
(at rated power)
>0.99
>0.99
(at rated power)
(at rated power)
96.5%
96.5%
0.11
0.11
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Integrated
Integrated
NEMA-6
NEMA-6
-40℃ ~+65℃
-40℃ ~+65℃
LED LIGHT
LED LIGHT
POWERLINE
POWERLINE
300*233*38mm
300*233*38mm
3
3
MODEL
Max Recommended PV Power (Wp)
Vmax PV (absolute maximum) (Vdc)
PV Input Operating Voltage Range (Vdc)
INPUT(DC)
Maximum Operating PV Input Current (Adc)
MPPT Tracking Accuracy
Isc PV (absolute maximum) (Adc)
Maximum Inverter Backfeed Current to the Array (Adc)
Max AC Output Power (W)
Nominal Power Grid Voltage (Vac)
Nominal Output Current (Aac)
Current (inrush) (Peak and Duration)
OUTPUT(AC)
Nominal Frequency (Hz)
Power Factor
Maximum Output Fault Current (Aac)
Maximum Output Overcurrent Protection (Aac)
SYSTEM
CEC Efficiency
Night Time Tare Loss (W)
EFFICIENCY
Over/Under Voltage Protection
Over/Under Frequency Protection
Anti-Islanding Protection
Over Current Protection
PROTECTION
Reverse DC Polarity Protection
FUNCTIONS
Overload Protection
Ground Fault Detection
Protective Class
IP Rating
Environment Temperature
Display
OTHER
Communications
PARAMETERS
Dimension (D-W-H mm)
Weight(Kg)
AU-1P20002G-230-EU
700x 4
62
33-55
18*4
>99.9%
25*4
0
2000
230
8.7
24A, 15us
50
>0.99
(at rated power)
18.0A peak
18
96.5%
0.11
Yes
Yes
Yes
Yes
Yes
Yes
Integrated
Integrate
I
IP66 / IP67
-40℃ ~+65℃
LED LIGHT
POWERLINE
300*233*38mm
3
15